Three 100G QSFP28 modules can provide the same aggregate Ethernet data rate while using very different optical architectures. A short connection between data center switches may use 100GBASE-SR4 over multimode fiber, while a 10km single-mode connection may require LR4 or CWDM4. The important difference is not simply transmission distance: each interface has its own wavelength plan, fiber arrangement, connector requirements, and host configuration.
These differences become particularly important when validating third-party optics on Cisco Catalyst and Nexus equipment. SR4, LR4, and CWDM4 modules may all fit into a QSFP28 port, but physical fit does not establish optical interoperability. Even LR4 and CWDM4, which both use duplex LC connectors over single-mode fiber, cannot automatically be substituted for one another.
A reliable validation process must therefore examine three separate questions: does the Cisco switch recognize the module, does the optical interface match the remote endpoint, and can the completed link carry 100GbE traffic without unacceptable errors?
1. The Optical Architecture Behind SR4, LR4 and CWDM4
The three interfaces use different methods to transport 100G-class data across an optical link. Understanding their channel arrangements is essential before starting any interoperability test.
| Parameter | 100GBASE-SR4 | 100GBASE-LR4 | 100G CWDM4 |
|---|---|---|---|
| Optical wavelength | 850nm | Four LAN-WDM wavelengths around 1310nm | Four CWDM wavelengths around 1270–1330nm |
| Fiber type | Multimode fiber | Single-mode fiber | Single-mode fiber |
| Optical architecture | Four parallel transmit and four parallel receive lanes | Four wavelength-multiplexed channels | Four wavelength-multiplexed channels |
| Typical connector | MPO-12 | Duplex LC | Duplex LC |
| Common reach | 70m OM3 / 100m OM4 | 10km | 2km |
| Fiber arrangement | Parallel multimode fibers | Two single-mode fibers | Two single-mode fibers |
| FEC consideration | Verify the selected module and host requirements | Standard LR4 does not require FEC | Check the module and host RS-FEC requirements |
100GBASE-SR4: parallel multimode transmission
SR4 uses four optical transmit lanes and four receive lanes. Each lane operates at approximately 25.78Gb/s, using 850nm VCSEL technology over multimode fiber.
The MPO-12 connector provides the parallel optical interface. Eight fiber positions are used for the four transmit and four receive channels, while the complete MPO connector contains 12 fiber positions.
Standard reach depends on the installed fiber grade. Cisco specifies up to 70m on OM3 and 100m on OM4 for its QSFP-100G-SR4-S module. This makes SR4 suitable for connections inside data halls, between racks, and between nearby network devices.
100GBASE-LR4: LAN-WDM over single-mode fiber
LR4 transmits four optical channels in the LAN-WDM wavelength region around 1310nm. The channels are multiplexed inside the transceiver and travel through one single-mode fiber in each direction.
Cisco's QSFP-100G-LR4-S specification identifies four nominal wavelength channels at approximately 1295nm, 1300nm, 1304nm, and 1309nm. The module supports up to 10km over standard G.652 single-mode fiber using duplex LC connectors.
Unlike some other 100G optical implementations, Cisco specifies that its standard LR4 module does not employ host FEC. This distinction is important when reviewing interface configuration and link requirements.
100G CWDM4: coarse wavelength multiplexing
CWDM4 also uses four optical channels, but its wavelength plan is different from LR4. The commonly specified channel centers are 1271nm, 1291nm, 1311nm, and 1331nm.
All four channels are multiplexed onto a duplex single-mode fiber connection through LC connectors. A common CWDM4 implementation supports up to 2km, making it suitable for connections between data center areas, campus equipment rooms, and nearby facilities.
CWDM4 is associated with the CWDM4 MSA ecosystem. Its optical specifications and interoperability requirements should be evaluated separately from IEEE 100GBASE-LR4, even though both use a QSFP28 form factor and duplex single-mode fiber.
2. Which Modules Can Be Connected Directly?
Optical compatibility is determined by the physical-layer interface, not by the shared 100G data rate. The following combinations provide a useful starting point for building a validation plan.
| Module at End A | Module at End B | Fiber Infrastructure | Direct Link Assessment |
|---|---|---|---|
| SR4 | SR4 | Compatible MMF with correct MPO polarity | Valid optical pairing |
| LR4 | LR4 | SMF with duplex LC | Valid optical pairing |
| CWDM4 | CWDM4 | SMF with duplex LC | Valid optical pairing |
| SR4 | LR4 | MMF or SMF | Not a standard interoperable pairing |
| SR4 | CWDM4 | MMF or SMF | Not a standard interoperable pairing |
| LR4 | CWDM4 | SMF with duplex LC | Not a standard interchangeable pairing |
| SR4 segment | LR4 segment | Separate optical links through a switch | Valid mixed-media network architecture |
Cross-vendor testing should be performed within each matching optical category. For example, a third-party SR4 module can be paired with a Cisco SR4 module, while a third-party CWDM4 module can be evaluated against another CWDM4-compliant module.
When a network needs to connect an SR4 access segment to an LR4 or CWDM4 backbone, a switch can terminate each independent optical link and forward Ethernet frames between them. The modules do not need to communicate directly with each other across the same passive fiber connection.
3. How to Distinguish LR4 from CWDM4 During Module Selection
LR4 and CWDM4 deserve additional attention because they share several physical characteristics: QSFP28 form factor, four optical channels, single-mode fiber, and duplex LC connectors. A visual inspection of the modules or patch cords cannot establish whether they have matching optical characteristics.
| Optical Parameter | 100GBASE-LR4 | 100G CWDM4 |
|---|---|---|
| Channel plan | LAN-WDM | CWDM |
| Nominal channel centers | 1295.56, 1300.05, 1304.58, 1309.14nm | 1271, 1291, 1311, 1331nm |
| Fiber | G.652 SMF | SMF |
| Connector | Duplex LC | Duplex LC |
| Typical specified reach | 10km | 2km |
| FEC behavior | Cisco standard LR4 specifies no FEC | Host RS-FEC requirements depend on the defined implementation and platform |
For example, Cisco lists QSFP-100G-LR4-S and QSFP-100G-CWDM4-S as separate products. The LR4 uses the LAN-WDM channel plan and supports 10km, while the CWDM4 module uses the four CWDM channels and supports 2km.
This distinction should be reflected in product ordering, switch compatibility records, and optical test reports. A module advertised with a generic description such as "100G QSFP28 LC 10km" still needs its actual channel plan verified before being treated as an LR4 interface.
4. Cisco Switch Compatibility and Supported Optical Modules
Once the optical interface is identified, the next question is whether the Cisco device supports the selected transceiver. Cisco's 100G product portfolio includes separate part numbers for SR4, LR4, and CWDM4 modules.
| Cisco Optical Module | Optical Interface | Fiber | Reach | Connector |
|---|---|---|---|---|
| QSFP-100G-SR4-S | 100GBASE-SR4 | MMF | 70m OM3 / 100m OM4 | MPO-12 |
| QSFP-100G-LR4-S | 100GBASE-LR4 | SMF | 10km | Duplex LC |
| QSFP-100G-CWDM4-S | 100G CWDM4 | SMF | 2km | Duplex LC |
Cisco platforms with selected 100G QSFP28 interfaces include Catalyst 9500X and 9600 configurations, as well as multiple Nexus 9000 systems. Exact support depends on the switch SKU, port configuration, line card, and software release.
Use the Cisco Optics-to-Device Compatibility Matrix to check platform and software requirements. Cisco also provides an Optics Interoperability Matrix for supported module-to-module combinations.
As one platform-specific example, Cisco's published Catalyst 9300X compatibility information lists separate entries for QSFP-100G-CWDM4-S and QSFP-100G-LR4-S. These entries include the corresponding fiber type, connector, transmission distance, and IOS XE software requirements. Such entries are useful evidence that identical form factors do not mean identical supported optical configurations.
5. A Three-Part Validation Process for Cisco QSFP28 Modules
A useful test result separates host recognition, optical connectivity, and Ethernet traffic performance. These stages help determine whether a fault originates from the switch, transceiver, or fiber channel.
Stage 1: Confirm host recognition
First record the switch model and software release. Then inspect the installed transceiver and relevant interface information.
show version show inventory show interfaces status show logging
On supported IOS XE systems, the interface and transceiver information may be available through the following command:
show interfaces HundredGigE1/0/1 transceiver detail
For supported Nexus NX-OS systems, the corresponding command format is typically:
show interface ethernet 1/1 transceiver details
Command availability and interface naming differ between platforms. Check the relevant Cisco command reference before applying these examples.
Record the module vendor, part number, serial number, wavelength information where available, and any unsupported-module messages. Module recognition is a host compatibility check, not proof of successful optical transmission.
Stage 2: Verify the physical optical link
Use the fiber infrastructure that matches the selected PMD:
SR4: Compatible OM3 or OM4 multimode fiber, MPO-12 connectors, and correct polarity.
LR4: Single-mode G.652 fiber, duplex LC, and compatible LAN-WDM channel plans at both ends.
CWDM4: Single-mode fiber, duplex LC, and compatible four-channel CWDM wavelength plans.
Clean and inspect connectors before making the connection. For MPO links, confirm the fiber mapping and polarity. For duplex LC links, verify that the transmit path at one end is connected to the receive path at the other end.
Stage 3: Validate the Ethernet service
After the physical link is established, inspect the operational interface and traffic behavior.
show interfaces HundredGigE1/0/1 show interfaces counters errors show logging
Check the following items:
Port state and line protocol.
Operational speed and interface configuration.
Transmit and receive optical power, where DOM is available.
FEC status and error counters, where applicable.
CRC, input, and output error counters.
Link transitions during sustained operation.
Throughput and packet loss under controlled traffic testing.
A stable link with clean error counters and acceptable traffic performance provides stronger compatibility evidence than a port-up indication alone.
6. FEC Configuration: A Key Difference Between Optical Interfaces
FEC is an important part of 100G validation because the host port and optical module must operate with compatible signal-processing requirements. However, the same FEC setting should not be assumed for every QSFP28 optical interface.
Cisco specifies that its standard 100GBASE-LR4 module does not use host FEC. Its product documentation describes the LR4 optical interface as operating without FEC. CWDM4 configurations have different requirements; Cisco's documented 100G portfolio table identifies host RS-FEC based on IEEE Clause 91 for its CWDM4 module.
For SR4, FEC behavior should likewise be verified against the specific module, host platform, and port mode. A breakout configuration may have different requirements from an ordinary 100G port.
| Interface | FEC Validation Focus | Testing Requirement |
|---|---|---|
| 100GBASE-SR4 | Module and port implementation; breakout mode may affect requirements | Confirm the selected host configuration and monitor error counters. |
| 100GBASE-LR4 | Cisco standard LR4 specification does not employ FEC | Verify that the port is configured for the correct LR4 operating mode. |
| 100G CWDM4 | Host RS-FEC may be required for the specified implementation | Confirm Clause 91 support and compatible host settings. |
Do not force a universal FEC configuration across these three optical interfaces. Consult the exact module datasheet and Cisco platform documentation, then record the negotiated or configured FEC mode as part of the test report.
7. Optical Measurements and Link-Budget Evaluation
Optical power measurements help determine whether a module is receiving a signal within its specified operating range. This is particularly useful when a link is recognized but experiences intermittent errors or fails during traffic testing.
The basic optical power budget is calculated as:
Optical Power Budget (dB) = Minimum Transmitter Output Power (dBm) − Receiver Sensitivity (dBm)
The available budget must accommodate fiber attenuation, connector insertion loss, splice loss, and an engineering margin. The receiver's overload limit must also be checked, especially on short links with low total attenuation.
| Measurement | SR4 | LR4 | CWDM4 |
|---|---|---|---|
| Transmit optical power | Check each transmit lane | Check each LAN-WDM channel | Check each CWDM channel |
| Receive optical power | Check each receive lane | Verify the received WDM signal against module limits | Verify the received CWDM signal against module limits |
| Fiber attenuation | Evaluate multimode channel loss | Evaluate single-mode channel loss | Evaluate single-mode channel loss |
| Connector inspection | MPO end-face condition and polarity | Duplex LC condition and polarity | Duplex LC condition and polarity |
| Receiver overload | Check per-lane receiver limits | Check receiver input-power limits | Check receiver input-power limits |
| Diagnostic monitoring | Lane-level DOM where provided | DOM readings where supported | DOM readings where supported |
For parallel SR4 links, aggregate optical power alone may not reveal a weak individual lane. Where diagnostic information is available, examine lane-level measurements. For LR4 and CWDM4, the optical signal is wavelength-multiplexed, so the module's diagnostic capability and available channel-level information should be considered.
8. C-LIGHT 100G QSFP28 Products for SR4, LR4 and CWDM4 Evaluation
C-LIGHT's 100G QSFP28 portfolio includes parallel multimode SR4 products and wavelength-multiplexed single-mode products. The exact optical channel plan and product datasheet should be checked before selecting a module for a Cisco interoperability test.
| C-LIGHT Model | Published Optical Description | Fiber | Reach | Connector | Published Case Temperature |
|---|---|---|---|---|---|
| CL100GQSFPSR4 | 100G SR4, 850nm | MMF | 70m OM3 / 100m OM4 | MTP/MPO-12 | 0°C to +70°C in the linked PDF |
| CL100GQSFPCW4-02 | 100G CWDM4, four CWDM channels | SMF | 2km | Duplex LC | 0°C to +70°C |
| CL100GQSFPCLR4 | Product page uses LR4 naming; linked datasheet identifies CWDM4 wavelengths | SMF | 10km | Duplex LC | 0°C to +70°C |
100G QSFP28 SR4: CL100GQSFPSR4
The C-LIGHT CL100GQSFPSR4 uses 850nm VCSEL technology and an MTP/MPO-12 interface. Its published specifications list 70m over OM3 and 100m over OM4, an aggregate data rate of 103.125Gb/s, and DDM/DOM support.
The downloadable CL100GQSFPSR4 datasheet specifies a 0°C to +70°C operating case-temperature range and power consumption below 2.5W. These specifications should be used for the exact model and document revision being evaluated.
100G QSFP28 CWDM4: CL100GQSFPCW4-02
The C-LIGHT CL100GQSFPCW4-02 is a 2km single-mode CWDM4 module. Its published specifications list four optical channels at 1270nm, 1290nm, 1310nm, and 1330nm, with duplex LC connectors and an aggregate data rate of 103.1Gb/s.
The corresponding CWDM4 2km datasheet lists a commercial case-temperature range of 0°C to +70°C and power dissipation below 3.5W.
Important product identification note for the 10km LR4 listing
C-LIGHT also publishes a product page titled 100G QSFP28 LR4 Optical Transceiver, associated with model CL100GQSFPCLR4. However, its downloadable datasheet identifies the module as QSFP28 100GBASE-CWDM4 10KM and lists 1270nm, 1290nm, 1310nm, and 1330nm channels.
These are CWDM-style channel centers, not the LAN-WDM wavelength plan specified for standard IEEE 100GBASE-LR4. Therefore, the product title alone should not be used to claim interoperability with a standard Cisco LR4 module. The exact channel plan and interoperability specification should be confirmed with C-LIGHT before selecting it for an LR4 cross-vendor link.
For projects requiring standard 100GBASE-LR4 interoperability, confirm that the selected module uses the required LAN-WDM channel plan and meets the relevant optical specifications. This distinction prevents a single-mode, duplex-LC module from being incorrectly classified as interchangeable with every other 100G LC optical module.
9. Building a Repeatable Cisco 100G Optical Test Matrix
For network integrators and optical transceiver suppliers, one successful link test is not sufficient to qualify an entire product family. The result should be tied to the exact optical model, Cisco platform, software release, and fiber configuration.
| Validation Category | Test Item | Pass Criteria |
|---|---|---|
| Host compatibility | Cisco hardware and software identification | Test platform and release are documented; module behavior matches the applicable support policy. |
| Module identification | EEPROM and transceiver inventory | Module information is read as expected. |
| Optical matching | SR4, LR4, or CWDM4 pairing | Both ends use compatible optical physical-layer interfaces. |
| Fiber qualification | MMF or SMF, connector, polarity, and distance | The installed channel meets the applicable link specification. |
| FEC validation | Host FEC requirements and operating state | The selected configuration matches the module and platform documentation. |
| Optical diagnostics | Transmit and receive power, temperature, and alarms | Available readings remain within specified limits. |
| Traffic performance | Throughput, packet loss, and error counters | Results meet the defined test profile. |
| Stability | Link transitions and sustained operation | No unexplained link drops or abnormal error accumulation. |
Record the transceiver manufacturer, part number, serial number, optical interface, switch model, hardware revision, software version, port number, fiber type, cable length, FEC mode, and test date.
SR4, LR4, and CWDM4 should each have independent qualification results. A successful test using an MPO-based SR4 module does not establish compatibility for an LC-based LR4 or CWDM4 product. Similarly, CWDM4 interoperability should not be inferred from a successful LR4 test on the same switch.
10. Conclusion
100GBASE-SR4, 100GBASE-LR4, and 100G CWDM4 provide different optical solutions for 100GbE networks. SR4 uses 850nm parallel multimode transmission through MPO connectors, LR4 uses four LAN-WDM channels over duplex single-mode fiber for 10km links, and CWDM4 uses four CWDM channels for shorter single-mode connections.
The shared QSFP28 form factor does not make these interfaces interchangeable. Reliable Cisco compatibility testing must account for optical channel plans, fiber and connector requirements, host support, FEC settings, diagnostic measurements, and sustained traffic performance.
C-LIGHT offers 100G QSFP28 SR4 and CWDM4 configurations for different optical applications. For LR4 projects, the precise LAN-WDM channel plan should be confirmed against the chosen product datasheet. Testing the exact module on the intended Cisco platform is essential before treating a configuration as qualified for production deployment.
Evaluating 100G QSFP28 SR4, LR4, or CWDM4 modules for Cisco network equipment?
C-LIGHT can assist with optical interface selection, fiber infrastructure requirements, product specifications, and compatibility evaluation for your network project.