ADTRAN 100G QSFP28 SR4 and LR4 Module Compatibility Testing

By C-LIGHT Marketing 丨 Jul 23, 2025
Table of Contents

    10 Gigabit Ethernet uplinks are widely used in enterprise aggregation, data center access, broadband infrastructure, and service-provider networks. Within these environments, 10G SFP+ SR and LR optical transceivers provide two common connectivity options: short-reach multimode links and longer-reach single-mode links. Although both use the SFP+ form factor and support 10GbE transmission, their optical specifications and deployment requirements are different.

    For ADTRAN equipment, selecting an appropriate third-party SFP+ module requires checking the exact host platform, supported transceiver specifications, module identification, and fiber interface. A module that matches the general 10GBASE-SR or 10GBASE-LR specification is not automatically guaranteed to operate in every ADTRAN SFP+ port.

    1. ADTRAN 10G SFP+ SR and LR Compatibility Requirements

    ADTRAN equipment is deployed across multiple networking environments, including NetVanta platforms, Total Access 5000 systems, and SDX access products. Different equipment families support different pluggable optics, so compatibility should be established using the exact device model and port configuration.

    The ADTRAN Pluggable Optics Compatibility Matrix lists supported optical transceivers and their corresponding host modules. Its 10 GigE SFP+ entries include 850nm multimode and 1310nm single-mode options, with different reach specifications and supported host combinations.

    Before selecting an SR or LR module, verify the following:

    • Host model: Confirm that the exact ADTRAN platform and SFP+ port support the required optical interface.

    • Data rate: The host must support 10 Gigabit Ethernet operation.

    • Optical standard: Match the module type to the required SR or LR application.

    • Fiber type: SR normally uses multimode fiber, while LR uses single-mode fiber.

    • Module identification: Check whether the host accepts the module's EEPROM identification and coding.

    • Operating conditions: Confirm power consumption, temperature rating, and diagnostic support.

    SFP+ MSA and IEEE optical specifications provide a common technical foundation, but they do not establish universal host compatibility. ADTRAN's supported-host information and actual device testing remain important.

    2. 10GBASE-SR and 10GBASE-LR Optical Specifications

    The main difference between SR and LR is the optical medium and transmission reach. SR uses an 850nm optical interface for multimode fiber, while LR uses a 1310nm interface for single-mode fiber.

    Parameter10GBASE-SR10GBASE-LR
    Form FactorSFP+SFP+
    Data Rate10Gb/s Ethernet10Gb/s Ethernet
    Wavelength850nm1310nm
    Fiber TypeMultimode fiberSingle-mode fiber
    Typical ReachUp to 300m on OM3; up to 400m on OM4Up to 10km on single-mode fiber
    ConnectorDuplex LCDuplex LC
    Common ApplicationData center and campus connectionsEnterprise uplinks and longer-distance fiber links

    Actual transmission distance depends on the fiber grade, link loss, connector condition, and transceiver specifications. The distances above describe common IEEE application limits rather than a guarantee for every installed fiber route.

    10GBASE-SR: 850nm multimode transmission

    10GBASE-SR is designed for short-reach optical connections using multimode fiber. Its 850nm VCSEL-based optical interface makes it suitable for connections within data centers, equipment rooms, and campus facilities.

    Common SR deployments use OM3 or OM4 fiber with duplex LC connectors. OM4 fiber supports a longer reach than OM3 under the standard 10GBASE-SR application limits. Existing fiber infrastructure should be identified before selecting the module.

    10GBASE-LR: 1310nm single-mode transmission

    10GBASE-LR uses a 1310nm optical interface and single-mode fiber to support links up to 10km. It is commonly selected for building-to-building connectivity, service-provider aggregation, and enterprise network uplinks where multimode fiber reach is insufficient.

    LR modules typically use duplex LC connectors. Both endpoints should support compatible 10GBASE-LR interfaces, and the fiber path should meet the optical power budget of the selected transceivers.

    3. ADTRAN 10G SFP+ SR and LR Part Numbers

    ADTRAN's compatibility matrix contains multiple 10G SFP+ entries. The following examples illustrate the SR and LR options and the host platforms associated with them in the published matrix.

    ADTRAN Part NumberOptical TypeWavelengthFiberReachListed Host Platforms
    1700485F110GBASE-SR850nmMultimode, duplex300mNetVanta 1550 Series; selected SDX platforms
    1442401G110GBASE-SR850nmMultimode, duplex300mTotal Access 5000 SM, GigE and ONE; NetVanta NV800/NV8000; selected SDX platforms
    1700486F110GBASE-LR1310nmSingle-mode, duplex10kmNetVanta 1550 Series; selected SDX platforms
    1442410G110GBASE-LR1310nmSingle-mode, duplex10kmTotal Access 5000 SM, GigE and ONE; NetVanta NV800/NV8000; selected SDX platforms
    1442420G1Extended-reach 10G optical1310nmSingle-mode, duplex20kmTotal Access 5000 SM, GigE and ONE; NetVanta NV800/NV8000; selected SDX platforms

    The host lists above are summarized from ADTRAN's published compatibility matrix. They should not be generalized to every device in the same product family. In particular, the 20km 1442420G1 entry is an extended-reach 10G option and should not be treated as a standard 10GBASE-LR specification.

    4. Fiber Infrastructure and Optical Link Requirements

    Even when both ADTRAN endpoints recognize their installed SFP+ modules, the physical fiber link must still meet the requirements of the selected optical interface. Fiber type, connector condition, polarity, and total insertion loss all influence link performance.

    Multimode fiber for SR connections

    SR modules are commonly used with OM3 and OM4 multimode fiber. The fiber grade determines the supported reach, while patch-panel connections and additional connector pairs contribute to the total insertion loss.

    • Use compatible multimode fiber at both ends.

    • Confirm the installed fiber grade and route length.

    • Use matching duplex LC connections and correct polarity.

    • Inspect and clean connectors before testing.

    • Check receive optical power against the transceiver's specified limits.

    Single-mode fiber for LR connections

    LR modules are designed for single-mode fiber and are commonly deployed over OS2 cabling. They support longer links than SR modules and are suitable for connections between network rooms, buildings, and aggregation locations.

    • Confirm that the installed fiber is single-mode.

    • Verify that the route length is within the transceiver's rated reach.

    • Measure total link loss where the optical budget is uncertain.

    • Check connector cleanliness and fiber polarity.

    • Confirm that received optical power is within the specified operating range.

    5. Optical Power Budget and Receive-Level Validation

    Optical power budget is a key factor in determining whether an SR or LR connection can operate reliably. A module's rated transmission distance does not replace an actual link-budget calculation.

    The available optical budget can be calculated as:

    Optical Power Budget = Minimum Transmitter Output Power − Receiver Sensitivity

    The available budget must accommodate the combined loss of the fiber, connectors, splices, and other passive components. Engineers should also consider engineering margin and the receiver's maximum input power.

    Validation ParameterPurposeWhat to Check
    Transmit PowerConfirms optical output from the local moduleWithin the module's specified minimum and maximum levels
    Receive PowerConfirms signal level at the remote receiverAbove receiver sensitivity and below overload limit
    Fiber Insertion LossMeasures attenuation through the installed linkWithin the calculated optical budget
    TemperatureMonitors operating conditionsWithin the transceiver's rated temperature range
    Link Error CountersIdentifies physical or traffic-related problemsNo unexpected increase in errors during testing

    DDM or DOM readings can help monitor transmit power, receive power, module temperature, supply voltage, and laser bias current when supported by both the transceiver and host. These readings should be interpreted against the module datasheet rather than treated as universal pass/fail thresholds.

    6. SFP+ EEPROM Coding and ADTRAN Module Recognition

    Host recognition is separate from optical compatibility. SFP+ transceivers contain EEPROM identification data that allows the network device to read module information through the management interface.

    Depending on the equipment, the host may check vendor identification, part number, revision, supported interface, and diagnostic capabilities. Some platforms also apply vendor-specific compatibility policies.

    When a module is not recognized, engineers should check:

    • Whether the exact ADTRAN platform supports the optical module category.

    • Whether the module's identification data is accepted by the host software.

    • Whether the installed software release has specific transceiver requirements.

    • Whether system logs report an unsupported module or hardware warning.

    • Whether the module is operating within the host's power and thermal limits.

    Changing module identification data does not resolve an optical mismatch or guarantee safe operation. Compatibility should be established using the equipment manufacturer's supported requirements and appropriate device-level validation.

    7. ADTRAN 10G SFP+ SR and LR Interoperability Testing

    A reliable interoperability evaluation should verify the complete link rather than stopping when the interface reports an operational state. Testing should use the target ADTRAN model, software release, transceiver revision, and remote-end equipment planned for deployment.

    Host recognition testing

    Install the selected module and confirm that the ADTRAN platform detects it correctly. Review interface status, module information, and system logs. Record any unsupported-module messages or diagnostic warnings.

    Optical interface testing

    For SR, confirm 850nm multimode operation and the correct fiber grade. For LR, confirm 1310nm single-mode operation and the intended link distance. Verify that both endpoints use compatible optical interfaces.

    Link establishment testing

    Check that the interface reaches the expected 10GbE operating state. Confirm that both endpoints report stable link status and that no unexpected link transitions occur during the test period.

    Traffic and error testing

    Run bidirectional Ethernet traffic using an appropriate test setup. Review packet loss, frame errors, interface counters, and link stability. A successful link-up indication alone does not demonstrate that the connection can sustain the intended network workload.

    Thermal and sustained-operation testing

    Monitor module temperature and diagnostic parameters during sustained operation where supported. For equipment installed in environments with elevated or low ambient temperatures, verify that the selected module's temperature rating is appropriate for the deployment.

    8. Common SR and LR Compatibility Issues

    ProblemPossible CauseRecommended Check
    Module not recognizedHost restriction, unsupported coding, or software requirementCheck ADTRAN compatibility information and module identification
    SR link does not come upSingle-mode fiber, incorrect polarity, or incompatible remote opticsVerify 850nm multimode interfaces and fiber connections
    LR link does not come upMultimode fiber, incorrect remote optics, or excessive path lossVerify 1310nm single-mode interfaces and optical power
    Receive power too lowDirty connectors, excessive attenuation, or damaged fiberInspect connectors and measure the complete optical path
    Intermittent linkMarginal optical budget, unstable connection, or thermal conditionsReview DDM readings, error counters, and environmental conditions
    Link up but traffic errors increasePhysical-layer errors or endpoint configuration problemsRun sustained bidirectional traffic tests and review interface counters

    9. C-LIGHT 10G SFP+ SR and LR Product Options

    C-LIGHT offers a range of 10G SFP+ optical transceivers for multimode and single-mode network applications. The portfolio includes 850nm SR modules, 1310nm LR modules, and extended-reach options for longer single-mode links.

    Representative products listed in the C-LIGHT 10G SFP+ portfolio include:

    C-LIGHT Part NumberOptical TypeWavelengthFiber TypeListed DistanceConnector
    CLSFP8510GSR10GBASE-SR850nmMMF300mLC
    CLSFP1310GLR10GBASE-LR1310nmSMF10kmLC
    CLSFP1310GLR20Extended-reach 10G1310nmSMF20kmLC
    CLSFP1310GLR40Extended-reach 10G1310nmSMF40kmLC

    The C-LIGHT product portfolio also lists multi-rate 1G/10.3G SFP+ options and industrial-temperature variants for selected models. Product selection should be based on the specific datasheet, host requirements, and operating environment.

    Relevant product information:

    For ADTRAN deployments, provide the equipment model, software version, required reach, fiber type, and target optical standard when requesting a module. This information helps determine the appropriate SR or LR configuration and whether additional host-specific validation is needed.

    10. Conclusion

    ADTRAN 10G SFP+ SR and LR transceivers support different fiber infrastructures and transmission distances. SR uses 850nm multimode optics for short-reach connections, while LR uses 1310nm single-mode optics for links typically reaching 10km. Extended-reach products require separate specification and host validation.

    Reliable interoperability depends on more than matching the SFP+ form factor. Engineers should verify the exact ADTRAN host model, supported module information, fiber interface, optical power budget, and Ethernet performance. C-LIGHT's 10G SFP+ portfolio provides SR, LR, and extended-reach options for evaluation against specific network requirements.