C-LIGHT telephone TEL:+86 132 6656 7067    
Language
C-LIGHT search
Comparison

400ZR vs 400ZR+

By C-LIGHT Marketing 丨 Mar 4, 2025
Table of Contents

    1. The Structural Difference: OIF-Fixed vs MSA-Flexible

    400ZR and 400ZR+ are not successive generations of the same specification. They are two coherent pluggable profiles defined by different bodies with different design objectives. 400ZR was defined by the Optical Internetworking Forum as a standardized, interoperable interface for short-reach data center interconnect. 400ZR+ is not an OIF designation; it is an MSA-driven extension that uses the same physical form factor and the same underlying coherent detection principle, but changes the FEC, the modulation options, and the reach envelope.

    The consequence is that 400ZR prioritizes interoperability and power efficiency, while 400ZR+ prioritizes reach and flexibility. A 400ZR module from one vendor should link with a 400ZR module from another without configuration negotiation. A 400ZR+ module from one vendor may or may not link with a 400ZR+ module from another, depending on whether both implement the OpenZR+ MSA modes and whether their firmware and DSP are compatible in the selected operating mode.

    One-line distinction: 400ZR is a fixed, interoperable DCI profile. 400ZR+ is a reach-extended, mode-flexible profile. The first is specified for predictability; the second is specified for span margin.

    2. Reach: Fixed ~120 km vs Amplified 500–600 km

    2.1 400ZR Reach Envelope

    400ZR is designed for point-to-point links up to approximately 120 km in unamplified or single-span amplified configurations. Its reach is bounded by two factors: the chromatic dispersion tolerance of the DP-16QAM signal and the coding gain of C-FEC. The fixed configuration is adequate for metro DCI where the fiber span is short and the optical path is simple, but it does not provide the margin needed for multi-span amplified routes or for ROADM traversal.

    2.2 400ZR+ Reach Envelope

    400ZR+ extends the reach through two mechanisms. First, oFEC provides substantially higher net coding gain than C-FEC, allowing the receiver to recover a signal at a lower optical signal-to-noise ratio. Second, the optional QPSK and 8QAM modulation formats trade capacity for reach: QPSK is more robust than 16QAM and can traverse longer spans at the same OSNR. In amplified links, 400ZR+ reaches the 500 km class and beyond; the C-LIGHT CL400GQDDZR+HP is rated for amplified distances up to 500 km, with C-LIGHT specifying up to 600 km at 200G in ZR+ mode[reference:0][reference:1]. FS summarizes the 400ZR+ reach envelope as up to approximately 600 km using tunable C-band DWDM channels[reference:2].

    Reach Parameter400ZR400ZR+
    Unamplified reach~120 km~80–120 km (mode dependent)
    Amplified reachSingle-span, ~120 km class~500 km at 400G; ~600 km at 200G (C-LIGHT CL400GQDDZR+HP)
    ROADM traversalLimitedFlexible-grid ROADM with hybrid amplification support
    Chromatic dispersion robustnessBounded by C-FEC and 16QAMExtended by oFEC and optional QPSK/8QAM

    3. FEC: C-FEC vs oFEC

    3.1 C-FEC in 400ZR

    400ZR uses Concatenated FEC (C-FEC), a hard-decision code with a fixed overhead and a post-FEC error floor specified below 1.0×10⁻¹⁵. C-FEC is well matched to the short-reach DCI application: it provides sufficient coding gain for ~120 km spans and it is fully standardized, so that any compliant 400ZR module can decode it. The coding gain is real but bounded; it is not designed to recover signals that have traversed multiple amplified spans.

    3.2 oFEC in 400ZR+

    400ZR+ uses Open FEC (oFEC), the soft-decision code originally defined in the OpenROADM specifications and adopted by the OpenZR+ MSA. oFEC provides a significantly higher net coding gain than C-FEC—commonly cited in the 11.6 dB class with 15% overhead—which directly translates into the additional optical margin needed for amplified multi-span links. The C-LIGHT CL400GQDDZR+HP supports oFEC and SFEC configurations in ZR+ mode, and C-FEC in ZR mode, allowing the same module to operate across both reach regimes[reference:3].

    The FEC difference is the single most important technical lever behind the reach difference. A 400ZR module cannot decode oFEC, and a 400ZR+ module operating in oFEC mode cannot interoperate with a 400ZR module at the far end. The two profiles occupy different coding domains, not merely different distance ratings.

    4. Modulation: Fixed 16QAM vs Selectable QPSK/8QAM/16QAM

    400ZR is fixed at DP-16QAM. The single modulation format simplifies the DSP, reduces power, and guarantees that any two 400ZR modules will use the same constellation. 400ZR+ exposes a mode set: DP-16QAM for maximum capacity at shorter amplified reaches, DP-8QAM for an intermediate tradeoff, and DP-QPSK for maximum reach at reduced capacity. The OpenZR+ MSA version 3.0 added the ZR400-OFEC-8QAM mode alongside the existing 16QAM and QPSK modes, and the C-LIGHT CL400GQDDZR+HP supports 16QAM in its ZR+ configuration with optional PCS-16QAM and SFEC for further flexibility[reference:4][reference:5].

    The modulation flexibility is not a free upgrade. Each mode carries a different OSNR requirement and a different reach, and the two endpoints must be configured for the same mode. A 400ZR+ module operating in QPSK mode delivers less than 400G of client capacity—typically 200G or 100G—but can traverse spans that 16QAM cannot. The operator selects the mode according to the span budget, not according to a fixed profile.

    5. Power and Host Platform Implications

    400ZR modules typically consume around 15–18 W. 400ZR+ modules consume more, because oFEC decoding and the wider mode set require additional DSP resources. The C-LIGHT CL400GQDDZR+HP is specified at ≤18 W in ZR mode and ≤22 W in ZR+ mode, with a maximum of 23 W[reference:6][reference:7]. FS cites 400ZR+ power draw in the 18–22 W range, and Approved Networks places the C-FEC 400ZR at 16–18 W and the oFEC 400ZR+ at 18–22 W[reference:8][reference:9].

    In a line card populated with multiple modules, this difference accumulates. A platform designed for 400ZR at a given port count may require derating or additional cooling to support 400ZR+ modules at the same density. The selection between the two profiles is therefore not purely a fiber-reach decision; it is also a thermal and power-delivery decision at the host platform level.

    Dimension400ZR400ZR+
    Standard bodyOIFOpenZR+ MSA (and proprietary variants)
    FECC-FEC (hard-decision)oFEC (soft-decision); optional SFEC/PCS
    ModulationDP-16QAM (fixed)DP-QPSK / DP-8QAM / DP-16QAM / PCS-16QAM
    Amplified reach~120 km class~500–600 km class
    Client flexibility400G nominalBreakout: 4×100G, 2×100G, 1×100G
    Typical power~15–18 W~18–23 W
    InteroperabilityDesigned for multi-vendorOpenZR+ modes support multi-vendor; proprietary modes may not

    6. C-LIGHT 400G Coherent Product

    6.1 CL400GQDDZR+HP: 400ZR+ High Power

    The C-LIGHT CL400GQDDZR+HP is a 400G ZR+ DCO QSFP-DD transceiver built on the ZR+ MSA, with a full C-band tunable laser, flex-grid support down to 6.25 GHz, and an integrated EDFA plus tunable optical filter. It supports 400G/200G/100G coherent optical interfaces, 4×100GbE and 400GbE host configurations, and operates in both ZR (C-FEC) and ZR+ (oFEC/SFEC) modes. Amplified reach is specified up to 500 km at 400G, extending to 600 km at 200G in ZR+ mode. Power consumption is ≤18 W in ZR mode and ≤22 W in ZR+ mode (23 W maximum), over a 0–75°C case temperature range. The module is compliant with OpenZR+ MSA 2.0, OIF 400ZR, and IEEE 802.3cw[reference:10][reference:11].

    Product link: C-LIGHT CL400GQDDZR+HP 400G ZR+ High Power Coherent QSFP-DD Transceiver

    Datasheet: CL400GQDDZR+HP Datasheet (PDF)

    6.2 400G ZR+ Family Variants

    C-LIGHT also offers a 300 km ZR+ variant (CL400GQDDZR+-300) and a 120 km ZR variant (CL400GQDDZR-120) within the same product family, allowing the reach tier to be matched to the link budget without changing the host interface or form factor. The 400G ZR family page lists these variants with C-band tunable wavelengths across 1528.77–1566.52 nm and duplex LC connectors[reference:12].

    Product link: C-LIGHT DWDM 400G ZR+ Product Family

    7. Conclusion

    400ZR and 400ZR+ differ in the three dimensions that determine what a coherent pluggable can do with a given fiber span. 400ZR is an OIF-standardized, fixed-profile interface: DP-16QAM, C-FEC, ~120 km reach, ~15–18 W power, designed for interoperable short-reach DCI. 400ZR+ is an MSA-driven extension: oFEC, selectable QPSK/8QAM/16QAM, amplified reaches in the 500–600 km class, and breakout client configurations, at 18–23 W and with the caveat that interoperability depends on both endpoints implementing the same mode. The choice between them is set by the span loss, the presence of amplified or ROADM segments, the surrounding network’s rate structure, and the host platform’s thermal envelope—not by which label carries a “plus.” C-LIGHT’s CL400GQDDZR+HP covers the 400ZR+ application space with integrated EDFA, full C-band tuning, and dual ZR/ZR+ operating modes, and the family’s 300 km and 120 km variants allow the reach tier to be matched to the deployment without changing the module footprint.

    8. Frequently Asked Questions

    Q1: Is 400ZR+ just a longer-reach version of 400ZR?
    In effect, but the difference is more than distance. 400ZR+ changes the FEC from C-FEC to oFEC and opens the modulation set to QPSK/8QAM/16QAM. The longer reach follows from those changes, not from a single reach rating.
    Q2: Can a 400ZR module interoperate with a 400ZR+ module?
    Generally no, in the extended-reach modes. 400ZR uses C-FEC and DP-16QAM; 400ZR+ extended modes use oFEC and may use QPSK or 8QAM. The two profiles operate in different coding and modulation domains. A 400ZR+ module in ZR mode may interoperate with 400ZR, depending on implementation.
    Q3: What is the maximum amplified reach of 400ZR+?
    Commonly cited in the 500–600 km class. C-LIGHT specifies the CL400GQDDZR+HP at up to 500 km at 400G and up to 600 km at 200G in ZR+ mode. FS cites up to ~600 km with tunable C-band DWDM channels.
    Q4: How much more power does 400ZR+ consume?
    400ZR typically draws 15–18 W. 400ZR+ typically draws 18–22 W, with some variants reaching 23 W. The C-LIGHT CL400GQDDZR+HP is ≤18 W in ZR mode and ≤22 W in ZR+ mode.
    Q5: What modulation formats does 400ZR+ support?
    DP-QPSK, DP-8QAM, DP-16QAM, and in some implementations PCS-16QAM. The OpenZR+ MSA v3.0 added the ZR400-OFEC-8QAM mode. 400ZR is fixed at DP-16QAM.
    Q6: Does 400ZR+ support breakout to 100G?
    Yes. 400ZR+ supports client configurations such as 4×100G, 2×100G, and 1×100G, allowing a 400G module to serve a 100G-based network without stranding capacity. The C-LIGHT CL400GQDDZR+HP supports 4×100GbE, 2×100GbE, and 400GbE host interfaces.
    Q7: What FEC does 400ZR+ use?
    oFEC, the soft-decision Open FEC originally defined in OpenROADM and adopted by the OpenZR+ MSA. It provides substantially higher net coding gain than the C-FEC used in 400ZR, which is the primary enabler of the extended reach.
    Q8: Which C-LIGHT module should I use for 400G ZR+ up to 500 km?
    The CL400GQDDZR+HP is rated for amplified distances up to 500 km at 400G, with integrated EDFA, tunable optical filter, full C-band tuning, and ≤22 W power in ZR+ mode. C-LIGHT also offers a 300 km variant (CL400GQDDZR+-300) and a 120 km ZR variant (CL400GQDDZR-120).
    Q9: Is 400ZR always 120 km?
    The OIF 400ZR specification targets point-to-point reaches of approximately 120 km in unamplified or single-span amplified configurations. Some vendor literature cites a 40 km unamplified rating with amplification extending to 120 km; the practical envelope depends on the fiber and the link budget. The fixed C-FEC is the binding constraint on reach.
    Q10: Where can I find C-LIGHT’s 400G coherent product line?
    C-LIGHT’s 400G coherent family includes the CL400GQDDZR+HP (400ZR+ high power, 500 km+), CL400GQDDZR+-300 (300 km ZR+), and CL400GQDDZR-120 (120 km ZR), all in QSFP-DD form factor with C-band tunable wavelengths. Product pages and datasheets are linked in Section 6.

    Note: Reach figures, power consumption, and supported modes vary by module implementation, host platform, firmware version, and the specific MSA or OIF profile. The OpenZR+ MSA specification is versioned (v3.0, July 2023); deployment decisions should verify the operating mode and firmware compatibility of both endpoints. C-LIGHT product specifications are as published on c-light.com and c-light.cn; verify current availability and compliance with C-LIGHT directly.

    For any questions, please contact us by email or WhatsApp.

    Email: sales@c-light.com