100G FR4 and 100G LR4 are four-wavelength optical interfaces designed for high-speed Ethernet transmission over single-mode fiber. Both commonly use QSFP28 modules, four optical channels, and a duplex LC connection. Their main distinction is the optical wavelength plan and specified transmission distance: FR4 targets links up to 2 km, while LR4 supports links up to 10 km.
1. The Optical Design Behind 100G FR4 and 100G LR4
Both interfaces transmit an aggregate data rate of 100 Gb/s using four optical lanes. Each lane carries approximately 25 Gb/s, and wavelength-division multiplexing combines the four channels onto one transmit fiber. At the receiving end, a demultiplexer separates the incoming wavelengths before photodetection.
The key difference is the wavelength plan. 100G FR4 is commonly implemented according to the 100G 4WDM-10 Multi-Source Agreement (MSA), which specifies four CWDM wavelengths. 100G LR4 follows the IEEE 100GBASE-LR4 specification and uses four LAN-WDM wavelengths clustered more closely around 1310 nm.
In both designs, the four transmit channels share one fiber, while the four receive channels travel over a separate fiber. This arrangement enables full-duplex transmission through a standard duplex single-mode fiber link.
2. 100G FR4 vs 100G LR4: Key Specifications
| Parameter | 100G FR4 | 100G LR4 |
|---|---|---|
| Data rate | 100 Gb/s | 100 Gb/s |
| Optical lanes | 4 | 4 |
| Lane rate | Approximately 25.78 Gb/s | Approximately 25.78 Gb/s |
| Modulation | NRZ | NRZ |
| Wavelength plan | Four CWDM wavelengths | Four LAN-WDM wavelengths |
| Nominal center wavelengths | 1271, 1291, 1311 and 1331 nm | 1295.56, 1300.05, 1304.58 and 1309.14 nm |
| Fiber type | Single-mode fiber | Single-mode fiber |
| Fiber connection | Duplex LC | Duplex LC |
| Specified reach | Up to 2 km | Up to 10 km |
| Common form factor | QSFP28 | QSFP28 |
| Specification basis | 100G 4WDM-10 MSA | IEEE 100GBASE-LR4, IEEE 802.3 Clause 88 |
These are representative interface characteristics. Exact optical power limits, receiver sensitivity, transmitter characteristics, power consumption, and host electrical requirements should be checked against the specific module datasheet and applicable specification revision.
3. Wavelength Allocation: CWDM vs LAN-WDM
100G FR4: Four CWDM Channels
100G FR4 uses four nominal wavelengths at 1271 nm, 1291 nm, 1311 nm, and 1331 nm. The channels are spaced 20 nm apart, following the wavelength allocation defined by the 4WDM-10 MSA. The relatively wide spacing is characteristic of CWDM-based transmission.
Each wavelength carries one 25G-class NRZ optical signal. A wavelength multiplexer combines the four channels for transmission, and a corresponding demultiplexer separates them at the receiving end. This four-channel arrangement supports the 2 km application range associated with FR4.
100G LR4: Four LAN-WDM Channels
100G LR4 uses four nominal wavelengths at 1295.56 nm, 1300.05 nm, 1304.58 nm, and 1309.14 nm. These channels are closely spaced within the LAN-WDM region near 1310 nm.
The narrower wavelength spacing requires the optical transmitter and multiplexing components to maintain the specified channel characteristics. The LR4 optical design is intended to meet the link requirements for transmission over distances up to 10 km on single-mode fiber.
| Channel | FR4 nominal wavelength | LR4 nominal wavelength |
|---|---|---|
| Lane 0 | 1271 nm | 1295.56 nm |
| Lane 1 | 1291 nm | 1300.05 nm |
| Lane 2 | 1311 nm | 1304.58 nm |
| Lane 3 | 1331 nm | 1309.14 nm |
The channel plans are fundamentally different. An FR4 receiver is designed for the FR4 wavelength set, while an LR4 receiver is designed for the LR4 wavelength set. Matching the aggregate data rate and connector type does not make the two optical interfaces interchangeable.
4. Transmission Distance and Link Budget
The specified reach is one of the most important distinctions when planning a 100G optical link. FR4 is intended for connections up to 2 km, making it suitable for shorter single-mode fiber links. LR4 extends the target distance to 10 km and is commonly used for longer connections within data center campuses, enterprise networks, and metropolitan access environments.
Distance alone does not determine whether a link will work. The optical link budget must account for transmitter output power, receiver sensitivity, fiber attenuation, connector loss, splice loss, and any additional passive components in the path.
| Design consideration | FR4 link | LR4 link |
|---|---|---|
| Target reach | Up to 2 km | Up to 10 km |
| Fiber infrastructure | Single-mode fiber | Single-mode fiber |
| Connector loss | Included in the applicable link budget | Included in the applicable link budget |
| Longer routes | Not the intended application beyond 2 km | Designed for links up to 10 km |
| Validation | Check end-to-end loss and module limits | Check end-to-end loss and module limits |
A link should be assessed using the actual module's minimum and maximum transmit power, receiver sensitivity, overload limit, and specified channel conditions. A nominal distance rating should not be treated as a substitute for a measured or calculated link budget.
5. Host Interface and Optical Compatibility
Common QSFP28 implementations of both FR4 and LR4 use four electrical lanes to connect with the host equipment. The optical side also carries four lanes, with each lane operating at approximately 25.78 Gb/s using NRZ signaling.
Although their lane structures are similar, the two module types use different optical channel assignments and optical specifications. An FR4 module connected directly to an LR4 module may fail to establish a link because the receiving side is not designed for the other module's wavelength plan and optical characteristics.
Compatibility checks should include:
Supported 100G port speed and QSFP28 form factor on the switch or router.
Supported optical interface type and module coding.
Host electrical lane configuration and applicable FEC settings.
Wavelength plan and optical transmitter/receiver specifications.
Fiber type, duplex LC polarity, and end-to-end link loss.
Module power consumption, temperature range, and equipment operating limits.
6. Typical Applications of 100G FR4 and 100G LR4
Where 100G FR4 Is Used
FR4 is suited to shorter single-mode fiber connections where the required distance is within its 2 km specification. Typical examples include links between nearby network rooms, adjacent buildings, and data center areas connected through short single-mode fiber routes.
Its four-channel CWDM architecture provides a 100G optical interface over a duplex fiber pair. It can be a practical option when the installed fiber route and optical loss fall within the FR4 module's operating limits.
Where 100G LR4 Is Used
LR4 is intended for longer single-mode fiber connections, with a specified reach of up to 10 km. It is commonly considered for campus backbone links, data center inter-building connections, and enterprise or service-provider aggregation networks.
Where network equipment is separated by several kilometers, LR4 provides additional reach compared with FR4 while retaining a four-wavelength, duplex-fiber architecture.
7. Choosing Between 100G FR4 and 100G LR4
The selection should begin with the actual fiber route rather than the module name or connector type. If the link is no longer than 2 km and the optical budget is suitable, FR4 may meet the requirement. If the route approaches or exceeds 2 km but remains within 10 km, LR4 is the more appropriate interface to evaluate.
Other factors can affect the final choice, including the switch platform's supported optics, installed fiber quality, connector and splice losses, module availability, power consumption, and network maintenance requirements.
| Network requirement | Interface to evaluate |
|---|---|
| Single-mode link up to 2 km | 100G FR4 or LR4, subject to equipment support and link budget |
| Single-mode link from 2 km to 10 km | 100G LR4 |
| Four-wavelength CWDM channel plan | 100G FR4 |
| IEEE 100GBASE-LR4 interface | 100G LR4 |
| Existing FR4 or LR4 infrastructure | Use matching optical interfaces at both ends |
8. Conclusion
100G FR4 and 100G LR4 both provide 100 Gb/s transmission over duplex single-mode fiber using four optical wavelengths. Their principal differences are the wavelength allocation and transmission reach. FR4 uses four CWDM channels and is designed for links up to 2 km, while LR4 uses four LAN-WDM channels and supports links up to 10 km.
For network deployment, the appropriate choice depends on the fiber route, optical link budget, host equipment support, and required interface specification. Checking these parameters before installation helps avoid wavelength mismatches and unexpected link failures.
For 100G optical connectivity requirements, module compatibility, or application-specific solutions, contact our team for further technical assistance.