100G CWDM4 and 100G LR4 are designed for single-mode fiber networks, but they use different wavelength plans and target different transmission distances. CWDM4 combines four widely spaced wavelengths around 1271nm, 1291nm, 1311nm, and 1331nm to support links up to 2km. LR4 uses four closely spaced LAN-WDM channels around 1310nm and supports links up to 10km. Both commonly use QSFP28 modules and duplex LC connectors, making their physical appearance similar despite important differences in optical operation.
1. What Is a 100G CWDM4 Optical Transceiver?
100G CWDM4 is a 100Gbps optical interface defined by the CWDM4 Multi-Source Agreement (MSA). It uses four optical channels, each carrying approximately 25Gbps, to deliver an aggregate data rate of 100Gbps.
The four channels operate at nominal wavelengths of 1271nm, 1291nm, 1311nm, and 1331nm. These wavelengths are combined through coarse wavelength-division multiplexing and transmitted over a single-mode fiber. At the receiving end, a demultiplexer separates the channels for optical detection.
A typical CWDM4 module uses a QSFP28 package and duplex LC connector. It is designed for transmission distances up to 2km over single-mode fiber, making it suitable for connections between nearby data center buildings, campus facilities, and network aggregation equipment.
2. What Is a 100G LR4 Optical Transceiver?
100G LR4, formally known as 100GBASE-LR4, is a 100 Gigabit Ethernet optical interface standardized by IEEE 802.3. It also uses four optical channels, each carrying approximately 25Gbps, but employs a LAN-WDM wavelength plan.
The nominal channel wavelengths are 1295.56nm, 1300.05nm, 1304.58nm, and 1309.14nm. These closely spaced channels are multiplexed onto one single-mode transmit fiber and separated at the receiver.
LR4 commonly uses a QSFP28 package with duplex LC connectivity and supports transmission distances up to 10km under the specified optical link conditions. It is widely used in enterprise backbone networks, campus networks, and data center interconnect applications.
3. Key Technical Specifications
| Parameter | 100G CWDM4 | 100G LR4 |
|---|---|---|
| Specification | CWDM4 MSA | IEEE 802.3 100GBASE-LR4 |
| Typical form factor | QSFP28 | QSFP28 |
| Aggregate data rate | 100Gbps | 100Gbps |
| Optical channels | 4 | 4 |
| Lane rate | Approximately 25.78Gbps | Approximately 25.78Gbps |
| Modulation | NRZ | NRZ |
| Wavelength plan | CWDM | LAN-WDM |
| Nominal wavelengths | 1271 / 1291 / 1311 / 1331nm | 1295.56 / 1300.05 / 1304.58 / 1309.14nm |
| Fiber type | Single-mode fiber | Single-mode fiber |
| Fiber count | 2 | 2 |
| Connector | Duplex LC | Duplex LC |
| Maximum reach | 2km | 10km |
| Typical application | Short-reach single-mode data center links | Campus, enterprise backbone, and longer data center links |
The wavelength values represent nominal channel centers. Actual operating ranges and optical limits are specified by the applicable MSA or IEEE interface documentation. Individual module specifications, including transmit power, receiver sensitivity, power consumption, and temperature range, vary by manufacturer.
4. Wavelength Architecture: CWDM vs LAN-WDM
The most fundamental technical difference is the wavelength spacing used to transmit the four optical channels.
100G CWDM4: Wider Channel Spacing
CWDM4 uses four wavelengths separated by approximately 20nm. The wider spacing allows the module to combine four optical signals using a coarse WDM architecture. Its nominal wavelength channels are:
| Channel | Nominal Wavelength |
|---|---|
| Channel 1 | 1271nm |
| Channel 2 | 1291nm |
| Channel 3 | 1311nm |
| Channel 4 | 1331nm |
The relatively wide channel spacing provides room for practical wavelength tolerances and supports a compact four-channel optical architecture. CWDM4 is designed around the 2km application rather than the longer reach of LR4.
100G LR4: Closely Spaced LAN-WDM Channels
LR4 uses four wavelength channels grouped much more closely around the 1310nm region. Their nominal channel centers are approximately 1295.56nm, 1300.05nm, 1304.58nm, and 1309.14nm.
The LAN-WDM architecture supports the 10km link requirement while maintaining four independent optical channels on a duplex single-mode fiber connection. Its optical filtering and wavelength-control requirements differ from those of CWDM4.
5. Transmission Distance and Optical Link Budget
CWDM4 and LR4 are designed for different link distances, so their optical budgets must be evaluated according to their respective specifications.
| Parameter | 100G CWDM4 | 100G LR4 |
|---|---|---|
| Specified reach | Up to 2km | Up to 10km |
| Fiber type | Single-mode fiber | Single-mode fiber |
| Optical architecture | Four CWDM channels | Four LAN-WDM channels |
| Channel loss design | Specified by CWDM4 MSA | IEEE 100GBASE-LR4 channel budget |
| Typical deployment | Shorter building-to-building links | Longer campus and backbone links |
The CWDM4 MSA defines optical transmitter and receiver characteristics for its 2km application. LR4 is designed around a 10km application and has an IEEE-specified maximum channel insertion-loss allowance of 6.3dB.
Actual achievable distance depends on fiber attenuation, connector loss, splice loss, patch panels, and the total channel insertion loss. A 2km CWDM4 link or a 10km LR4 link should therefore be evaluated using the complete installed fiber path rather than distance alone.
6. Transmitter and Receiver Characteristics
Both modules use four optical transmit lanes and four receive lanes internally, but their wavelength requirements and link budgets influence the optical components and circuit design.
CWDM4 modules use optical sources and wavelength-multiplexing components designed for the four CWDM channels. LR4 modules use components designed for the narrower LAN-WDM wavelength ranges. The two architectures therefore require different optical filtering and wavelength-control characteristics.
The receiver must also meet the sensitivity and overload limits defined by its interface specification. These parameters determine how much optical loss the link can tolerate and how much received power can be accepted without exceeding the receiver's operating range.
Specific laser technologies, photodetector types, and optical subassemblies can vary between manufacturers. It is therefore better to compare the actual transmitter and receiver specifications than to assume that every CWDM4 or LR4 module uses an identical internal component design.
7. Fiber and Connector Requirements
Both CWDM4 and LR4 use single-mode fiber and commonly feature duplex LC connectors. One fiber carries the multiplexed transmit channels, while the other carries the receive channels.
OS2 single-mode fiber is commonly used for these applications. However, the supported reach depends on the relevant interface specification and the actual attenuation of the installed fiber plant.
Installation checks should include:
Confirming that the fiber is single-mode and suitable for the required wavelength range.
Checking connector cleanliness and end-face condition.
Verifying transmit and receive fiber polarity.
Measuring total channel insertion loss where required.
Including patch panels, connectors, and splices in the optical budget.
Checking the transceiver's minimum and maximum received optical power.
Although the two interfaces commonly use the same LC connector, their optical wavelength plans are different. Physical connector compatibility does not establish optical interoperability.
8. FEC and Host Interface Requirements
Forward Error Correction (FEC) is an important consideration when deploying 100G CWDM4. The CWDM4 MSA optical specification is designed around a receiver BER requirement that is supported by host-side error correction in typical implementations. Common QSFP28 CWDM4 deployments therefore require the appropriate host FEC configuration, often using KR4 FEC.
100GBASE-LR4 follows a different host-interface specification and is commonly deployed without the same host-side KR4 FEC requirement. This difference can affect switch configuration and interoperability.
Actual host behavior depends on the switch platform, firmware, port mode, and module implementation. Before connecting the modules, confirm the supported FEC mode at both endpoints and verify that the equipment vendor documents the intended interface combination.
9. Cost, Power Consumption, and Deployment Considerations
CWDM4 is generally positioned as a cost-effective solution for 2km single-mode connections. Its wavelength architecture is intended to meet shorter-reach requirements without the full reach capability of LR4.
LR4 supports a longer transmission distance and is designed for a different optical budget. Its optical components and wavelength-control requirements may influence module cost and power consumption.
Actual prices and power figures vary by supplier, product generation, and optical component design. A fair evaluation should compare the exact product datasheets rather than rely on a universal cost or power difference.
Existing fiber infrastructure is another important factor. If a network only needs to connect two nearby buildings over a short single-mode route, CWDM4 may be sufficient. If the connection extends beyond 2km and remains within 10km, LR4 is generally the more appropriate standard interface.
10. Can 100G CWDM4 and 100G LR4 Be Interchanged?
100G CWDM4 and 100G LR4 are not directly interchangeable, even though both commonly use QSFP28 modules, duplex LC connectors, and single-mode fiber.
Their optical wavelengths are different. CWDM4 uses 1271nm, 1291nm, 1311nm, and 1331nm nominal channels, whereas LR4 uses four LAN-WDM channels around 1310nm. A CWDM4 receiver is not designed to operate as an LR4 receiver simply because the connector fits.
Connecting a CWDM4 module at one end to an LR4 module at the other should not be assumed to establish a working link. The optical channels, receiver filtering, and host-side requirements must match.
When replacing one interface with the other, both endpoints should use compatible modules unless a specifically designed optical conversion or interworking solution is provided. Host compatibility and FEC configuration should also be verified.
11. How to Choose Between 100G CWDM4 and 100G LR4
The choice should be based on transmission distance, optical architecture, fiber infrastructure, and the capabilities of the host equipment.
Choose CWDM4 for single-mode fiber connections up to 2km when the host supports the CWDM4 interface and required FEC configuration.
Choose LR4 for single-mode fiber connections requiring up to 10km reach under the IEEE 100GBASE-LR4 specification.
Check the wavelength plan: Confirm that both ends use compatible CWDM or LAN-WDM optical interfaces.
Verify the fiber budget: Include fiber attenuation, connector losses, splice losses, and passive components.
Confirm connector requirements: Both commonly use duplex LC, but connector similarity does not guarantee optical compatibility.
Review FEC settings: Check the switch platform's supported FEC modes and the requirements of the exact transceiver.
Compare total cost: Include transceiver cost, fiber infrastructure, installation, power consumption, and future network expansion.
12. Conclusion
100G CWDM4 and 100G LR4 both provide 100Gbps connectivity through four optical channels over duplex single-mode fiber. Their main differences are wavelength spacing, optical architecture, and transmission reach.
CWDM4 uses four widely spaced wavelengths at 1271nm, 1291nm, 1311nm, and 1331nm and supports links up to 2km. LR4 uses four closely spaced LAN-WDM wavelengths around 1310nm and supports links up to 10km under the IEEE specification.
CWDM4 is suitable for shorter single-mode fiber connections, while LR4 provides greater reach for campus and backbone networks. Selecting the correct module requires checking the wavelength plan, optical link budget, FEC configuration, and host compatibility rather than relying on connector type or form factor alone.
Review the required transmission distance, wavelength plan, single-mode fiber characteristics, optical budget, and host compatibility before selecting a module. For product specifications and technical support, Contact C-LIGHT.