AI CPO vs AI Pluggable Optics: Architecture, Power Efficiency, Port Density and Serviceability

By C-LIGHT Marketing 丨 Nov 15, 2025
Table of Contents

    The rapid development of artificial intelligence, hyperscale computing and large GPU clusters is increasing the bandwidth and power requirements of modern data center networks. As switch ASICs move toward 800G, 1.6T and higher-capacity interfaces, conventional optical interconnect architectures face greater challenges involving electrical signal loss, front-panel density, power consumption and thermal management.

    Co-Packaged Optics (CPO) and conventional pluggable optical transceivers represent two different approaches to high-speed optical connectivity. Pluggable optics place optical engines inside removable modules installed at the front panel of a switch. CPO moves the optical engines close to the switching ASIC and integrates them within a coordinated package architecture.

    The main difference is the location of optical conversion. Pluggable optics maintain a longer electrical connection between the ASIC and front-panel module, while CPO significantly reduces this distance through package-level integration.

    This architectural change can improve bandwidth density and interconnect power efficiency, but it also affects serviceability, optical fiber routing, cooling, manufacturing yield and system maintenance. Both approaches have important roles in AI networking, and their suitability depends on the requirements of each network layer.

    1. What Is AI Pluggable Optics?

    Pluggable optics refers to removable optical transceiver modules installed in compatible switch, router, server or network interface card ports. These modules convert electrical signals from the host equipment into optical signals for fiber transmission and convert incoming optical signals back into electrical data.

    Conventional DSP-based pluggable transceivers typically contain optical transmitters, optical receivers, electrical interfaces and an integrated digital signal processor. The DSP performs signal conditioning and compensation to support reliable high-speed electrical and optical transmission.

    The module is inserted into a front-panel host cage, allowing the optical interface to be installed, removed and replaced independently of the main switch hardware.

    Different pluggable form factors are available for different bandwidth generations and system requirements, including QSFP-DD, OSFP, QSFP112 and OSFP112.

    Their main characteristics include:

    • Removable optical transceivers installed in front-panel cages.

    • Electrical-to-optical and optical-to-electrical conversion inside the module.

    • Multiple transmission distances and optical architectures.

    • Independent module replacement and maintenance.

    • Flexible use of different fiber types and optical connectors.

    • Established multi-vendor optical interoperability ecosystems.

    Pluggable optics can use multimode or single-mode fiber depending on the optical application. Short-reach options include SR and DR configurations, while FR, LR, ZR and other designs support different transmission distances and network requirements.

    Related C-LIGHT product: 800G OSFP Optical Transceiver

    C-LIGHT provides 800G OSFP optical transceivers with multiple configurations, including VR8, SR8, DR8 and 2xFR4. The product family covers different single-mode and multimode transmission requirements for AI clusters, data centers and high-performance computing.

    Product details:            C-LIGHT 800G OSFP Optical Transceiver

    2. What Is AI CPO?

    CPO stands for Co-Packaged Optics. It is an optical integration architecture that places optical engines close to a high-speed electronic ASIC, typically within the same advanced package or a tightly coupled package structure.

    In a conventional pluggable system, electrical signals travel from the switch ASIC across PCB traces and connectors before reaching the optical transceiver. As electrical signaling rates increase, this longer channel can create significant insertion loss and signal-integrity challenges.

    CPO reduces the distance between the electronic switching silicon and the optical conversion components. By locating optical engines close to the ASIC, the architecture shortens the high-speed electrical connection before data is converted into optical signals.

    The optical engines convert electrical signals into light, which travels through external fiber connections to remote network devices. At the receiving end, the corresponding optical engine performs optical-to-electrical conversion.

    Silicon photonics is an important technology in many CPO implementations. It allows optical functions such as waveguides, modulators and photodetectors to be integrated into compact photonic circuits.

    Some CPO systems use an external laser source (ELS) to supply continuous-wave optical power to the optical engines. This can separate laser components from the thermal environment surrounding the switch ASIC and provide additional flexibility for laser maintenance.

    The main characteristics of CPO include:

    • Optical engines integrated close to the switch ASIC.

    • Very short high-speed electrical connections.

    • Reduced electrical channel loss between the ASIC and optical engine.

    • High optical I/O density around the switching package.

    • Potential improvements in system-level interconnect power efficiency.

    • Advanced package-level optical, electrical and thermal integration.

    • More complex fiber attachment and system maintenance requirements.

    CPO is not a conventional pluggable module:

    The optical engines are integrated within the switch system rather than installed as removable front-panel transceivers. External fiber connections remain necessary, but the optical conversion components are positioned deeper inside the equipment.

    3. CPO vs Pluggable Optics: Core Technical Comparison

    CPO and pluggable optics can support high-speed optical connectivity, but their physical structures and system integration methods are fundamentally different.

    ParameterConventional Pluggable OpticsCPO
    Full NamePluggable Optical TransceiverCo-Packaged Optics
    Optical Engine LocationInside a removable front-panel moduleIntegrated close to the switch ASIC
    Integration LevelFront-panel module and host cageAdvanced ASIC and optical engine package integration
    Electrical PathPCB traces and connectors between ASIC and moduleShort package-level electrical connections
    Electrical Channel LossDepends on board-level trace and connector distanceReduced through close optical integration
    Signal ProcessingDSP or other module-side processing, depending on architectureDepends on ASIC and optical engine implementation
    Module ReplacementIndividual transceiver can normally be replacedNo conventional front-panel optical module replacement
    Power Efficiency PotentialDepends on module DSP, SerDes and optical enginePotentially higher through shorter electrical paths
    Bandwidth DensityLimited by front-panel cage area and module layoutPotentially higher optical I/O density around the ASIC
    Thermal DesignModule heatsink and host airflowCombined ASIC and optical engine thermal management
    MaintenanceEstablished module-level replacement proceduresMore dependent on package and optical engine service design
    System UpgradeModules can be upgraded within host compatibility limitsMore closely tied to ASIC and package generations
    Deployment ModelFlexible front-panel optical connectivityPurpose-built high-density optical switching system

    Pluggable optics emphasize flexibility and independent component replacement. CPO emphasizes integration, shorter electrical paths and optical bandwidth density.

    4. ASIC-to-Optics Electrical Path and Signal Integrity

    Electrical transmission distance is one of the primary reasons CPO is being developed for next-generation AI switches.

    In a traditional pluggable architecture, the switch ASIC is located on the main PCB, while the optical transceiver is installed at the front panel. High-speed electrical data must travel across PCB traces, connectors and the transceiver host interface before reaching the optical engine.

    As signaling rates increase, this electrical channel becomes more difficult to manage. Insertion loss, return loss, crosstalk, reflections and other high-frequency impairments can reduce the available signal margin.

    Conventional DSP-based optical modules compensate for some of these signal impairments through internal digital processing. This provides greater flexibility for different electrical channel conditions, but DSP processing adds module power consumption and heat.

    CPO changes the physical distance between the ASIC and optical conversion point. By placing optical engines close to the ASIC, it reduces the length of the highest-speed electrical path.

    ArchitectureSimplified Signal PathElectrical Connection
    Pluggable OpticsASIC → PCB → Host Connector → Optical Transceiver → FiberLonger board-level electrical channel
    CPOASIC → Package-Level Electrical Interface → Optical Engine → FiberShort package-level electrical connection

    The shorter electrical connection can reduce the amount of high-frequency electrical compensation required before optical conversion. This is especially valuable as AI switch platforms move toward higher electrical lane rates.

    However, CPO does not eliminate signal integrity requirements. Package routing, electrical impedance, optical engine characteristics and fiber coupling must still be validated across the complete system.

    5. Power Consumption and Energy Efficiency

    Power efficiency is one of the most important motivations behind CPO adoption in AI data centers. Large switches supporting many high-speed optical interfaces can generate substantial electrical and thermal loads.

    Conventional pluggable transceivers may use DSPs to process electrical signals before and after optical conversion. These components consume power and generate heat within individual front-panel modules.

    CPO moves optical engines close to the ASIC, shortening the high-speed electrical connection and reducing the need to drive signals through long PCB traces and connectors. This can improve interconnect energy efficiency.

    The power comparison must include the complete system. Optical engines, laser sources, electrical drivers, the switch ASIC, SerDes and cooling hardware all contribute to the total energy budget.

    Power FactorPluggable OpticsCPO
    Module DSPConventional DSP modules use module-side digital processingArchitecture depends on the optical engine and host implementation
    ASIC-to-Optics Electrical DriveMust support the board-level channel to the front panelShorter package-level electrical path
    Optical Engine PowerConsumed within each pluggable moduleConsumed by co-packaged optical engines
    Laser PowerProvided by the module's optical source architectureMay use integrated or external laser sources
    Electrical Signal ConditioningDepends on module DSP and host SerDes architectureShorter electrical path can reduce signal-driving requirements
    Thermal DistributionOptical module heat concentrated near front-panel cagesASIC and optical engine heat concentrated in an integrated package area
    System-Level EfficiencyDepends on optical module and host implementationPotentially higher through optimized electrical and optical integration

    An important distinction is that CPO's energy advantage should be assessed using consistent system boundaries. Comparing one CPO optical engine with a complete pluggable module, while excluding the host SerDes or external laser power, can produce misleading results.

    6. Optical Bandwidth Density and Port Scaling

    AI switches increasingly require high aggregate bandwidth and large numbers of optical connections. As switch ASIC capacity grows, conventional front-panel optical cages can consume substantial physical space.

    Pluggable optical modules use dedicated front-panel openings and connectors. The overall port density depends on the form factor, cage dimensions, heatsink design, airflow and available chassis space.

    CPO places optical engines around the switching ASIC rather than allocating all optical conversion components to the front panel. This allows designers to distribute optical I/O across the ASIC package architecture.

    The result can be higher optical bandwidth density within a switch system. However, the actual density depends on optical engine size, fiber attachment, package layout and cooling requirements.

    Design FactorPluggable OpticsCPO
    Optical Port LocationFront panelAround or within the ASIC package structure
    Port Density ConstraintCage spacing, connector size and airflowPackage dimensions, optical engine layout and fiber routing
    Bandwidth ScalingRequires additional or higher-capacity pluggable modulesCan integrate more optical I/O close to the ASIC
    Electrical ConnectivityMultiple PCB channels to front-panel modulesShort package-level electrical connections
    Mechanical SpaceFront-panel space is a major design factorInternal package and fiber-routing space becomes critical
    System ArchitectureModular transceiver-based switchingASIC and optical engine co-designed as an integrated system

    CPO has the potential to increase optical I/O density, particularly in high-radix AI switches. Pluggable optics continue to provide flexibility where front-panel port access, module replacement and different optical reach options are priorities.

    7. Thermal Management and Cooling Architecture

    Thermal management is an important challenge for both CPO and pluggable optics, but the physical location of heat-generating components is different.

    In a conventional pluggable system, optical transceivers are installed in front-panel cages. Their thermal performance depends on module power consumption, heatsink construction, airflow and the temperature of the surrounding switch environment.

    This physical separation allows optical modules to have their own thermal boundaries. A high-power switch ASIC and the optical transceivers can be managed through different thermal paths within the chassis.

    CPO places optical engines close to a high-power ASIC. Although the shorter electrical path can improve interconnect efficiency, the optical components operate in a more demanding thermal environment.

    The switch package must therefore manage heat from the ASIC and optical engines together. Thermal spreading, package materials, cooling hardware and the temperature sensitivity of optical components all influence system reliability.

    External laser sources can help separate the laser heat source from the ASIC package. In such designs, continuous-wave optical power is delivered to the optical engines through dedicated optical connections.

    Thermal Design FactorPluggable OpticsCPO
    Optical Engine LocationFront-panel transceiverClose to the switch ASIC
    Heat DistributionDistributed among ASIC, modules and chassis airflowConcentrated around ASIC and optical engine package
    Cooling MethodModule heatsink and host airflowCo-designed package and system cooling
    Thermal InteractionGreater physical separation between ASIC and transceiverStronger thermal coupling between ASIC and optical engines
    External Laser SourceDepends on the individual optical moduleUsed in many designs to separate laser components from the package
    Thermal QualificationModule case temperature and airflow testingASIC, optical engine, laser and package-level thermal testing

    CPO's lower electrical interconnect power does not eliminate thermal challenges. Its integrated structure requires coordinated cooling for the switching silicon and optical components, making thermal design a system-level engineering requirement.

    8. Serviceability and Module Replacement

    Serviceability is one of the strongest operational advantages of pluggable optical transceivers.

    When a pluggable optical module develops a fault, a technician can normally remove the module from the host cage and replace it with a compatible spare. This allows optical components to be maintained independently from the main switch ASIC.

    The same approach supports gradual upgrades. Network operators can replace modules according to changes in reach, speed, wavelength or optical interface requirements, provided the host platform supports the new modules.

    CPO changes this maintenance model. Optical engines are integrated close to the ASIC package and are not conventional front-panel transceivers.

    A fault involving a co-packaged optical engine or package-level interface can require more extensive diagnostics and repair. Depending on the system, maintenance may involve replacing an optical subassembly, circuit board or larger switch assembly.

    Some CPO systems use external laser sources that can be replaced independently. Certain optical engine designs may also retain modular mounting or detachable interfaces. However, these features should not be confused with the straightforward hot-swap capability of conventional front-panel optics.

    Maintenance FactorPluggable OpticsCPO
    Module ReplacementIndividual optical module replacementIntegrated optical engine or system-level service
    Hot-Swap SupportNormally supported by compatible host platformsNot equivalent to front-panel module hot swapping
    Fault IsolationModule-level diagnosis and replacementPackage, optical engine and fiber interface diagnosis
    External Laser MaintenanceDepends on module designMay be independently replaceable in ELS-based architectures
    Optical Engine ServiceEntire module can normally be removedDepends on package and optical engine mounting design
    Upgrade FlexibilityHigh within host compatibility limitsMore closely tied to the switch ASIC and package generation
    Operational ModelEstablished field-replacement proceduresMore integrated system maintenance

    This difference is important for large-scale AI infrastructure. A small increase in repair time or replacement complexity can become significant when a data center operates thousands of high-speed optical connections.

    9. Optical Fiber Routing and Connector Architecture

    Pluggable optics and CPO also differ in how optical fibers connect to the network equipment.

    In a conventional pluggable design, the optical transceiver is installed in a front-panel cage. The fiber patch cord connects directly to the optical connector on the removable module.

    This creates an easily accessible optical interface. Fiber patch cords, trunk cables and structured optical cabling systems can be organized through front-panel ports and patch panels.

    In CPO, optical engines are located inside the switch system near the ASIC. Optical fibers must be routed from these internal optical engines to external connection points.

    This requires precision fiber attachment, internal fiber routing and dedicated optical connector structures. Fiber attachment units (FAUs), fiber ribbons and high-density optical connectors may be used depending on the optical engine design.

    Fiber Connectivity FactorPluggable OpticsCPO
    Optical Connector PositionFront panel of the host systemExternal connection to internally integrated optical engines
    Fiber AttachmentDirect connection to removable modulePackage-level or internal optical engine attachment
    Fiber ManagementFront-panel patching and structured cablingInternal fiber routing and high-density connection management
    Connector MaintenanceAccessible front-panel cleaning and replacementDepends on the location and design of internal connection interfaces
    Fiber AlignmentStandard transceiver connector alignmentPrecision optical engine and fiber attachment alignment
    Installation ComplexityEstablished optical cabling processMore complex internal routing and assembly

    Optical fiber management becomes a critical reliability factor in CPO systems. Connector contamination, bending stress, mechanical strain and coupling accuracy can directly affect the performance of high-density optical connections.

    10. Power Efficiency and System Cost

    Power efficiency is one of the strongest technical motivations for CPO, but system cost should be considered alongside power consumption.

    Conventional pluggable systems use removable optical modules, established cages and front-panel fiber connections. These components provide flexibility and a mature replacement model, although module DSP power and long electrical connections can increase the overall power budget.

    CPO can reduce electrical interconnect power and increase optical density, but requires advanced packaging, optical engine integration, specialized fiber connections and more complex manufacturing processes.

    Total cost of ownership must also account for maintenance, replacement procedures, system downtime, spare inventory, package yield and cooling infrastructure.

    Cost FactorPluggable OpticsCPO
    Optical Component StructureIndependent removable transceiversIntegrated optical engines
    Module DSP PowerRequired in conventional DSP-based modulesDepends on the CPO optical engine architecture
    Electrical Interconnect PowerLonger ASIC-to-module electrical channelShort package-level electrical connection
    Manufacturing CostEstablished module manufacturing and assemblyAdvanced ASIC and photonic package integration
    Maintenance CostIndividual transceiver replacementDepends on optical engine modularity and switch repair model
    Inventory ManagementIndividual modules can be stocked as sparesMay require larger system-level spare assemblies
    System CoolingFront-panel module and airflow managementAdvanced package and ASIC cooling integration
    Total Cost EvaluationModule, power, installation and replacement costsPackage, optical engine, laser, cooling and lifecycle costs

    CPO may provide a power-efficiency advantage in high-bandwidth systems, but this does not automatically establish a lower overall purchase price or lifecycle cost. A fair comparison must evaluate equivalent network bandwidth, reach, system power boundaries and maintenance requirements.

    11. Application in AI Scale-Up and Scale-Out Networks

    AI data center networks use different interconnect architectures to connect accelerators, servers and switching equipment. Scale-up and scale-out networks have different physical and bandwidth requirements, influencing the suitability of CPO and pluggable optics.

    Scale-up networking connects accelerators and computing resources within a tightly coupled domain. Short electrical connections remain attractive within servers and racks because of their direct signaling architecture. As the physical network expands, optical connections become increasingly important.

    CPO can be relevant in high-bandwidth switches that aggregate large numbers of scale-up or scale-out links. Its optical engines are integrated around the ASIC, allowing high optical connectivity density with shorter electrical paths.

    Scale-out networking connects GPU servers and network switches across a larger fabric. Conventional pluggable optics remain attractive where individual link flexibility, different optical reaches and independent module replacement are important.

    Network ApplicationPluggable OpticsCPO
    GPU Server ConnectivityReplaceable optical modules for supported server and switch interfacesOptical engine integration within purpose-built switching systems
    Scale-Up SwitchingFlexible optical connections between compatible platformsHigh-density optical interfaces for advanced switching systems
    Scale-Out FabricSuitable for leaf-spine and other optical switch linksSuitable for high-radix switches requiring dense optical I/O
    Hyperscale Data CentersFlexible port-level expansion and maintenanceSystem-level bandwidth density and power optimization
    Data Center InterconnectBroad optical reach options, including longer-distance coherent modulesPrimarily focused on integrated optical switching connectivity
    Large AI GPU FabricsSupports varied endpoint and link requirementsPotentially beneficial for high-bandwidth aggregation layers

    CPO and pluggable optics are not restricted to mutually exclusive network layers. A hybrid network can use CPO in selected high-density switching platforms while retaining pluggable transceivers for access, aggregation and links requiring more flexible reach or maintenance.

    12. 800G and 1.6T Optical Interconnect Development

    The transition from 800G to 1.6T increases the requirements for optical bandwidth density, electrical lane performance and system-level thermal management.

    Conventional pluggable optics provide a clear upgrade path through different module generations and optical configurations. 800G OSFP and QSFP-DD products support different reach and fiber architectures, while next-generation 1.6T modules increase the aggregate optical capacity available from a single module.

    CPO takes a different path. Rather than relying exclusively on higher-capacity removable front-panel modules, it focuses on increasing optical I/O density around the switch ASIC and reducing high-speed electrical interconnect distance.

    Network GenerationPluggable Optics DevelopmentCPO Development
    400GEstablished QSFP-DD and OSFP optical transceiversIntegrated optical engines for selected switching architectures
    800G800G OSFP and QSFP-DD modules with SR, DR and FR configurationsHigh-density optical engines for advanced switching systems
    1.6THigher-rate pluggable optical transceivers using 200G-class electrical lanesGreater optical I/O density and reduced electrical path length
    Beyond 1.6TFurther evolution of pluggable form factors and optical enginesContinued scaling of photonic integration and package-level optical interfaces

    CPO does not automatically replace every optical module when network bandwidth increases. The appropriate technology depends on the switching architecture, required reach, port density, cooling design and operational requirements.

    13. Industry Deployment and Technology Maturity

    Pluggable optical transceivers have an established ecosystem covering different speeds, form factors, optical wavelengths and transmission distances. Their replaceable structure and broad compatibility make them suitable for a wide range of network equipment and data center environments.

    CPO has advanced from research and technology demonstrations into production use in selected high-density switching platforms. It requires coordinated development across switch ASIC design, silicon photonics, optical engine manufacturing, advanced packaging, external laser systems and fiber connectivity.

    The ecosystem is also developing through industry organizations that publish electrical, optical, mechanical and management interface specifications. These efforts are important for building interoperable optical engines and improving the reliability of integrated optical systems.

    Development FactorPluggable OpticsCPO
    Industry EcosystemEstablished optical module and host platform ecosystemDeveloping ecosystem across ASIC, photonics and packaging suppliers
    Manufacturing ProcessOptical module assembly and testingAdvanced package and optical engine integration
    InteroperabilitySupported by established form factors and optical standardsRequires coordinated optical engine and system interface specifications
    Supply ChainOptical modules, DSPs, lasers and connector suppliersASIC packaging, silicon photonics, optical engines, lasers and fiber assemblies
    Deployment FlexibilityBroad applications and network configurationsMore targeted to purpose-built high-density platforms
    Market RoleContinues to support a broad range of networking requirementsEmerging production architecture for selected high-bandwidth systems

    A notable industry development occurred in May 2026, when a CPO-based Ethernet switching platform was announced as being in production. This demonstrates that CPO has moved beyond laboratory demonstrations in selected commercial systems, although it does not indicate that pluggable optics have been replaced across the wider data center industry.

    14. How to Choose Between CPO and Pluggable Optics

    Choosing between CPO and pluggable optics requires a system-level assessment. The most important considerations include optical bandwidth density, electrical channel length, module replacement requirements, cooling capacity and lifecycle cost.

    Selection RequirementRecommended EvaluationEngineering Consideration
    Individual Optical Module ReplacementPluggable OpticsMaintains a removable front-panel optical interface
    High Optical I/O DensityCPOIntegrates optical engines close to the switching ASIC
    Reduced ASIC-to-Optics Electrical ReachCPOMinimizes high-speed electrical connection length
    Different Transmission DistancesPluggable OpticsSupports multiple module configurations and optical reach options
    Established Field MaintenancePluggable OpticsSupports conventional module replacement procedures
    Purpose-Built High-Radix SwitchingCPOSupports integrated optical connectivity around the ASIC
    Flexible Network ExpansionPluggable OpticsAllows independent changes to optical modules and link configurations
    System-Level Power OptimizationEvaluate CPO and pluggable alternativesCompare the complete ASIC, SerDes, optical engine and cooling power budget
    Long-Distance Optical LinksPluggable OpticsProvides broad short-, medium- and long-reach optical options

    Pluggable optics are suitable when flexibility, serviceability and multiple optical reach options are important. CPO is more attractive when a switch platform requires very high optical I/O density, reduced ASIC-to-optics electrical distance and system-level power optimization.

    Architecture selection should be based on the whole network:

    CPO is not automatically the best option for every AI data center connection. Different network layers have different distance, density and maintenance requirements. A combination of CPO and pluggable optics can provide a practical balance across large GPU clusters and hyperscale networks.

    15. C-LIGHT 800G and 1.6T Pluggable Optical Solutions

    C-LIGHT provides high-speed pluggable optical transceivers for AI data centers, GPU clusters, hyperscale cloud networks and high-performance computing systems.

    Its product portfolio includes 800G OSFP, 800G QSFP-DD and 1.6T OSFP-RHS optical transceivers. These products represent conventional pluggable optical solutions that provide flexible connectivity across different transmission distances and optical architectures.

    Product FamilyForm FactorOptical ConfigurationsListed Reach OptionsTypical Application
    800G OSFPOSFPVR8, SR8, DR8, 2xFR4 and other configurations50m, 100m, 500m and 2km for listed configurationsAI clusters and hyperscale data centers
    800G QSFP-DDQSFP-DDSR8, DR8, 2xFR4 and other configurations100m, 500m and 2km for listed configurationsHigh-density Ethernet and AI networks
    1.6T OSFP-RHSOSFP-RHS2xDR4 and 2xFR4500m and 2km for listed configurationsNext-generation AI and HPC networks
    C-LIGHT 800G OSFP Optical Transceiver

    The 800G OSFP product series includes short-reach multimode, parallel single-mode and wavelength-multiplexed optical configurations. These modules support different AI data center and high-performance networking link requirements.

    C-LIGHT 800G QSFP-DD Optical Transceiver

    The 800G QSFP-DD product series provides 800Gb/s optical connectivity for compatible high-density switch platforms, with multiple reach and optical interface options.

    C-LIGHT 1.6T OSFP-RHS Optical Transceiver

    The 1.6T OSFP-RHS product series includes 2xDR4 and 2xFR4 configurations for high-bandwidth AI and hyperscale data center connectivity.

    Product architecture clarification:

    The C-LIGHT products referenced above are pluggable optical transceivers. They are not CPO optical engines. CPO requires a different system architecture involving ASIC integration, optical engine placement, package design and external fiber connections. The product links are included as examples of the existing pluggable optical ecosystem.

    16. Conclusion

    AI CPO and conventional pluggable optics are two important approaches to high-speed optical connectivity in modern AI data centers. Their main difference is the position of the optical conversion components and the resulting system integration model.

    Pluggable optics place optical engines inside removable front-panel modules. They offer flexible optical configurations, independent module replacement, established interoperability and convenient maintenance. These characteristics make them suitable for a broad range of AI networking, Ethernet and data center interconnect applications.

    CPO integrates optical engines close to the switch ASIC, significantly shortening the high-speed electrical path. This creates opportunities for higher optical I/O density, reduced electrical signal loss and improved system-level power efficiency.

    The trade-off is greater package integration, more demanding thermal management, complex optical fiber routing and a different maintenance model. CPO is particularly relevant to purpose-built high-bandwidth switching platforms, while pluggable optics continue to provide flexibility across different network layers.

    As AI networks advance toward 800G, 1.6T and higher-speed optical connectivity, both technologies will remain relevant. Their adoption will depend on system bandwidth, electrical channel design, optical engine performance, cooling requirements, manufacturing capability and total lifecycle cost.

    C-LIGHT provides 800G OSFP, 800G QSFP-DD and 1.6T OSFP-RHS optical transceiver solutions for AI data centers, GPU clusters, cloud networks and high-performance computing applications. For product specifications, platform compatibility assessment or customized optical connectivity requirements, please Contact C-LIGHT.