What Is XPO in Optical Interconnect Technology?

By C-LIGHT Marketing 丨 Aug 6, 2025
Table of Contents

    As AI data centers expand to support larger GPU clusters and increasingly demanding workloads, network infrastructure must deliver more bandwidth within limited rack space. Conventional optical transceivers have enabled the transition from 400G to 800G and 1.6T connectivity, but increasing port density also creates challenges in signal integrity, power consumption and thermal management.

    XPO, short for eXtra-dense Pluggable Optics, is an emerging optical interconnect architecture developed to address these challenges. It introduces a high-density, liquid-cooled pluggable module designed for next-generation AI networks. The announced XPO architecture supports up to 12.8Tbps of bandwidth per module while retaining the serviceability of removable optical modules.

    Rather than replacing optical transmission technologies such as Ethernet or InfiniBand, XPO changes how high-bandwidth optical interfaces are packaged, cooled and integrated into network switches. It represents another approach to scaling optical connectivity as AI infrastructure moves toward multi-terabit links and increasingly dense switching systems.

    1. What Is XPO?

    XPO stands for eXtra-dense Pluggable Optics. It is a high-density pluggable optical module architecture introduced through an industry Multi-Source Agreement (MSA) organized by Arista Networks in March 2026.

    The architecture is designed for AI data centers and hyperscale networking environments where conventional front-panel optical interfaces may not provide sufficient bandwidth density or thermal capacity.

    The announced XPO design uses 64 high-speed electrical lanes, each operating at a nominal 200Gbps, to deliver an aggregate bandwidth of 12.8Tbps. It also incorporates an integrated liquid-cooling cold plate designed to support module power levels of approximately 400W or higher.

    Several characteristics define the XPO architecture:

    • High aggregate bandwidth: Up to 12.8Tbps per module in the announced implementation.

    • 64 electrical lanes: A high-density electrical interface designed around 200Gbps-per-lane signaling.

    • Liquid cooling: An integrated cold plate supports high-power operation.

    • Pluggable design: The module remains removable and serviceable rather than permanently integrated with the switch ASIC.

    • High front-panel density: The architecture targets significantly greater switching bandwidth within a limited rack-unit space.

    The important point is that XPO is a form-factor and system-integration development. It does not define a new Ethernet protocol, fiber type or modulation format by itself.

    2. How Does XPO Work?

    XPO combines a high-density electrical interface, optical transmission components and liquid-cooling hardware within a large pluggable module. Its purpose is to accommodate more high-speed signal channels and greater optical bandwidth without requiring the optics to be permanently integrated into the switch package.

    2.1 High-Density Electrical Interface

    The announced XPO architecture supports 64 high-speed electrical lanes. At a nominal rate of 200Gbps per lane, the aggregate bandwidth is:

    64 × 200Gbps = 12,800Gbps = 12.8Tbps

    This lane arrangement provides the electrical connectivity required to move large volumes of data between the host switching system and the optical module.

    High-speed electrical signaling at this density requires careful control of insertion loss, crosstalk, impedance discontinuities and signal integrity. The XPO connector and host-board design therefore play important roles in achieving the required performance.

    2.2 Optical Conversion and Fiber Connectivity

    On the optical side, the module converts electrical signals into optical signals for transmission through fiber. At the receiving end, optical signals are converted back into electrical signals for processing by the network equipment.

    XPO is intended to accommodate different optical reach categories, including DR, FR, LR, SR and ZR/ZR+ applications, depending on the implementation. These categories address different link distances and network requirements rather than representing different XPO form factors.

    The optical interface and fiber configuration still depend on the selected optical technology. Network designers must consider fiber type, connector configuration, wavelength, transmission distance and interoperability when planning an XPO-based network.

    2.3 Integrated Liquid Cooling

    Thermal management is one of the defining features of XPO. As the bandwidth and electrical lane count of optical modules increase, power consumption and heat generation become increasingly difficult to manage with conventional air cooling alone.

    XPO incorporates an integrated cold plate designed to transfer heat away from the module. The announced implementation targets cooling support of approximately 400W per module.

    This approach allows the optical interface to operate within a high-density, liquid-cooled switch environment. However, it also means that the switch chassis, coolant distribution system, mechanical interfaces and maintenance procedures must be designed to work with the module.

    3. Key Technical Specifications of XPO

    The following table summarizes the major characteristics of the XPO architecture announced in its initial MSA introduction. These figures describe the announced design and should not be interpreted as universal specifications for every future XPO implementation.

    ParameterXPO Architecture
    Full NameeXtra-dense Pluggable Optics
    Architecture TypeHigh-density pluggable optics
    Aggregate BandwidthUp to 12.8Tbps per module
    Electrical Lane Count64 lanes
    Nominal Lane Rate200Gbps per lane
    Cooling MethodIntegrated liquid-cooling cold plate
    Target Module Power SupportApproximately 400W or higher
    Optical ApplicationsDR, FR, LR, SR, ZR/ZR+ and other supported configurations
    Interface ArchitectureLinear, half-retimed or fully retimed options
    Primary ApplicationsAI data centers, hyperscale networks and high-bandwidth switching systems

    One distinction is particularly important: the 64 lanes refer to the high-speed electrical interface described by the XPO architecture. They should not automatically be interpreted as 64 separate optical wavelengths or 64 independent fiber channels.

    4. Why Is XPO Being Developed for AI Data Centers?

    AI infrastructure creates a different set of networking requirements from many traditional enterprise and cloud environments. GPU clusters exchange large volumes of data during distributed training and inference. As the number of accelerators increases, the network must provide higher aggregate throughput while maintaining predictable performance.

    4.1 Increasing Bandwidth Density

    Conventional pluggable optics have progressed through multiple generations, including 400G, 800G and 1.6T. However, increasing the number of optical ports can require more front-panel space and additional switch capacity.

    XPO aims to increase the amount of bandwidth supported by each module. Its announced 12.8Tbps capacity is eight times the aggregate bandwidth of a 1.6T module.

    This higher per-module capacity can help reduce the number of optical modules required for a given aggregate bandwidth target, although the actual system-level benefit depends on switch architecture, port configuration and network topology.

    4.2 Managing High Thermal Loads

    Higher electrical lane counts and optical bandwidth increase the importance of thermal design. In densely populated AI racks, the cooling capacity available to networking equipment is a major system-level constraint.

    XPO addresses this issue through an integrated liquid-cooling cold plate. Instead of relying exclusively on airflow across the module, the design provides a dedicated thermal path that can be integrated into a liquid-cooled switch platform.

    4.3 Reducing Front-Panel Space Requirements

    AI clusters require large numbers of high-speed connections between switches, compute nodes and other network elements. If each connection requires a separate conventional optical module, the number of front-panel interfaces can become a limiting factor.

    The XPO design is intended to increase front-panel bandwidth density. Arista's announced architecture targets up to 204.8Tbps of switching bandwidth within one Open Rack Unit (1OU), representing a fourfold density improvement compared with the referenced 1.6T OSFP implementation.

    4.4 Retaining Module Serviceability

    One of the practical advantages of pluggable optics is the ability to replace a module without replacing the entire switch or optical subsystem.

    XPO retains this removable-module concept. This is relevant for hyperscale operators managing large networks, where field replacement, maintenance time and component-level troubleshooting affect operational costs.

    5. XPO vs. OSFP: What Are the Differences?

    OSFP (Octal Small Form-factor Pluggable) is an established optical transceiver form factor used in high-speed data center networking. It supports multiple generations of optical connectivity, including 400G, 800G and 1.6T implementations.

    XPO takes a different approach by using a substantially larger, higher-density module designed for multi-terabit bandwidth and liquid cooling.

    FeatureOSFPXPO
    Form FactorEstablished compact pluggable form factorExtra-dense, larger pluggable form factor
    Example Bandwidth400G, 800G and 1.6TUp to 12.8T per announced module
    Electrical InterfaceDepends on module generation64 high-speed electrical lanes in the announced design
    CoolingCommonly air-cooled, depending on system designIntegrated liquid-cooling cold plate
    Front-Panel DensityEstablished high-density pluggable interfaceTargets up to 4× density versus the referenced 1.6T OSFP design
    ServiceabilityField-replaceableDesigned to remain pluggable and field-replaceable
    Typical PositioningCurrent high-speed data center connectivityNext-generation AI and hyperscale networking

    The difference is not simply that XPO is a faster version of OSFP. The two architectures have different physical dimensions, electrical interfaces and thermal requirements. XPO is intended for systems that need substantially greater bandwidth density than conventional pluggable modules can provide.

    6. XPO vs. CPO: Pluggable Optics or Co-Packaged Optics?

    CPO (Co-Packaged Optics) and XPO are two approaches to addressing the bandwidth and power challenges of next-generation switching systems. Both target high-performance networks, but they differ in how optical components are integrated into the switch.

    CPO places optical engines close to or within the switching ASIC package. This shortens the high-speed electrical connection between the switch silicon and optical conversion components.

    XPO, by contrast, retains a removable pluggable module architecture. It increases module capacity and integrates liquid cooling while keeping optical connectivity accessible as a replaceable component.

    FeatureCPOXPO
    Full NameCo-Packaged OpticseXtra-dense Pluggable Optics
    Optical PlacementNear or within the ASIC packageHigh-density pluggable module
    Electrical ConnectionVery short ASIC-to-optics connectionHigh-density electrical interface to the module
    Module ReplacementMore dependent on system architecture and service modelDesigned for field-replaceable modules
    CoolingIntegrated system and package thermal designIntegrated liquid-cooling cold plate
    Main AdvantageShort electrical paths and deep integrationHigh bandwidth density with pluggable serviceability
    Main ChallengePackaging, serviceability and system-level integrationModule size, liquid cooling and host-system compatibility

    Neither architecture is automatically suitable for every data center. CPO may be attractive when minimizing electrical reach is a primary design objective. XPO may be attractive when operators want much higher front-panel bandwidth density while retaining a replaceable optical module.

    7. XPO vs. NPO and LPO

    XPO is part of a broader development in optical interconnect packaging. NPO and LPO address related system challenges, but they are not interchangeable technologies.

    7.1 XPO vs. NPO

    NPO stands for Near-Packaged Optics. It places optical engines close to the switch ASIC or other high-speed processing components, reducing the electrical distance compared with conventional front-panel pluggable optics.

    XPO maintains a pluggable module architecture and focuses on increasing the bandwidth density of the removable optical interface. The distinction is primarily about optical placement and system integration.

    7.2 XPO vs. LPO

    LPO stands for Linear Pluggable Optics. It is an optical module approach that reduces or removes certain digital signal processing functions from the module, depending on the implementation. This can reduce power consumption and latency, but places greater demands on the host electrical channel and system signal integrity.

    XPO, on the other hand, defines a high-density pluggable architecture. The XPO MSA announcement describes support for linear, half-retimed and fully retimed interface architectures, allowing different signal-processing approaches within the broader form factor.

    TechnologyPrimary FocusOptical Position
    XPOExtreme pluggable bandwidth density and liquid coolingPluggable module
    NPOShorter electrical connections through near-package opticsNear the ASIC package
    LPOLower module power and reduced DSP processingPluggable module
    CPODeep optical integration and short electrical pathsWithin or alongside the ASIC package

    8. Where Can XPO Be Used?

    XPO is designed primarily for networking environments that require extremely high bandwidth density and advanced thermal management. Its potential applications extend across several parts of large-scale AI and cloud infrastructure.

    8.1 AI Scale-Up Networks

    Scale-up networks connect accelerators and other compute components within a tightly integrated system. These networks require high aggregate bandwidth and low-latency communication to support coordinated processing.

    XPO's high-capacity optical interface may support future system architectures that require dense connectivity between compute and switching components.

    8.2 AI Scale-Out Networks

    Scale-out networking connects multiple GPU servers, racks and switching layers. As clusters grow, the network must handle increasing traffic between distributed compute resources.

    High-density optical modules can help increase switch capacity while reducing the physical space required for front-panel connectivity.

    8.3 Scale-Across and Hyperscale Data Centers

    Large AI infrastructure may extend across multiple network domains, buildings or data center facilities. These environments require a combination of short-reach and longer-reach optical connections.

    The XPO MSA announcement identifies support for optical reach categories including DR, FR, LR, SR and ZR/ZR+, subject to the specific module implementation. This provides a framework for different connectivity requirements across AI and data center networks.

    8.4 High-Capacity Switching Systems

    Switch platforms designed for next-generation AI fabrics need to balance switching capacity, port density, power consumption and cooling. XPO is intended to support these system-level requirements through a high-bandwidth pluggable interface.

    9. Challenges and Considerations for XPO Deployment

    Although XPO offers a compelling approach to increasing optical bandwidth density, adopting it requires more than replacing conventional transceivers with a larger module.

    9.1 Liquid-Cooling Infrastructure

    XPO's integrated cold plate requires a compatible liquid-cooling environment. Data center operators must evaluate coolant distribution, thermal performance, leak management, service procedures and compatibility with the switch chassis.

    9.2 Host-System Compatibility

    XPO requires a compatible host connector, electrical interface, mechanical design and management implementation. Existing OSFP cages and switch front panels cannot be assumed to support XPO modules.

    9.3 Power Delivery

    Supporting high-power optical modules requires appropriate power distribution and protection. The switch platform must be designed to deliver stable power while managing the electrical and thermal requirements of the complete module.

    9.4 Fiber Management

    Increasing bandwidth density can also increase the complexity of fiber routing and maintenance. Operators need to consider connector access, fiber bend radius, cable organization, labeling and service clearance when designing high-density optical systems.

    9.5 Interoperability and Ecosystem Maturity

    The XPO MSA is intended to establish a common framework for multi-vendor development. However, an MSA announcement does not automatically guarantee that every module, host platform and optical configuration will interoperate.

    Compatibility should be validated against the applicable XPO specification, host implementation, optical configuration and vendor qualification requirements before deployment.

    10. How Does XPO Fit into the Evolution of Optical Interconnects?

    Optical interconnect development is moving along several paths. Conventional pluggable optics continue to increase lane rates and aggregate bandwidth. LPO explores lower-power signal-processing architectures, while NPO and CPO move optical conversion closer to the switching silicon.

    XPO takes a different route: it retains pluggability but expands the module's bandwidth capacity and thermal-management capabilities.

    The following table provides a simplified view of how these technologies address different system requirements.

    TechnologyDevelopment DirectionPrimary Design Goal
    Conventional Pluggable Optics400G, 800G, 1.6T and future generationsScalable, replaceable optical connectivity
    LPOReduced module DSP processingLower power and latency
    NPOOptics positioned near the ASICShorter electrical paths
    CPOOptics integrated near or within the ASIC packageDeep integration and electrical efficiency
    XPO12.8T high-density liquid-cooled pluggable architectureHigher front-panel bandwidth density with module serviceability

    These technologies are not necessarily competing replacements for one another in every deployment. Their suitability depends on switching architecture, thermal infrastructure, operational requirements, optical reach and the total cost of ownership.

    11. C-LIGHT Optical Transceivers for High-Speed Data Center Networks

    As data center networks move toward higher port speeds and denser optical connectivity, the selection of transceivers, fiber assemblies and interconnect solutions remains an important part of network planning.

    Although XPO represents an emerging high-density pluggable architecture, established optical transceiver platforms such as 400G, 800G and 1.6T continue to play an important role in current AI and hyperscale data center deployments.

    C-LIGHT provides optical transceiver solutions for different data center bandwidth requirements, including:

    These products represent established high-speed optical connectivity options and should not be confused with XPO modules. XPO requires its own compatible host interface and system design. As the industry develops higher-density optical platforms, the choice of transceiver architecture will depend on the bandwidth, cooling, interoperability and serviceability requirements of each network.

    12. Frequently Asked Questions About XPO

    Q1: What does XPO stand for in optical networking?

    XPO stands for eXtra-dense Pluggable Optics. It is a high-density optical module architecture designed for next-generation AI data centers and hyperscale networks.

    Q2: What is the bandwidth of an XPO optical module?

    The announced XPO architecture supports up to 12.8Tbps per module, using 64 high-speed electrical lanes operating at a nominal 200Gbps per lane.

    Q3: Does XPO use liquid cooling?

    Yes. The announced XPO design incorporates an integrated liquid-cooling cold plate intended to support module power levels of approximately 400W or higher.

    Q4: Is XPO the same as CPO?

    No. CPO places optical engines close to or within the switch ASIC package, while XPO retains a removable, high-density pluggable module architecture.

    Q5: What is the difference between XPO and OSFP?

    OSFP is an established pluggable form factor used for 400G, 800G and 1.6T connectivity. XPO is a larger, higher-density architecture designed for up to 12.8Tbps per module and integrated liquid cooling.

    Q6: Is XPO designed for Ethernet or InfiniBand?

    XPO is a physical module architecture rather than a networking protocol. Its optical implementation can be designed for different network technologies, subject to the module, host platform and interoperability requirements.

    Q7: Can an XPO module be installed in an OSFP port?

    No. XPO uses a different physical and electrical interface. A compatible switch platform and host design are required; an OSFP cage should not be assumed to support XPO.

    Q8: What are the main applications of XPO?

    Its primary target applications include AI scale-up and scale-out networks, hyperscale data centers, high-capacity switching systems and other bandwidth-intensive infrastructure.

    Q9: Does XPO replace conventional optical transceivers?

    Not necessarily. Conventional 400G, 800G and 1.6T modules remain important for existing networks. XPO targets systems with more demanding bandwidth-density and thermal requirements.

    Q10: Is XPO already a universal industry standard?

    XPO is being developed through a Multi-Source Agreement. The MSA provides a framework for ecosystem alignment, but product availability and interoperability still depend on implementation and qualification.

    13. Conclusion

    XPO introduces a new direction for high-density optical interconnects. By combining 64 high-speed electrical lanes, up to 12.8Tbps of aggregate bandwidth, integrated liquid cooling and a removable module design, it aims to address the growing connectivity demands of AI data centers.

    Its most important distinction is the balance between bandwidth density and serviceability. Rather than moving all optical components directly into the switch package, XPO seeks to extend the capabilities of pluggable optics into a much higher-performance class.

    As AI networks continue to scale, XPO, CPO, NPO and advanced conventional pluggable optics may serve different roles. The right architecture will depend on system bandwidth, electrical reach, thermal design, maintenance requirements and ecosystem maturity.