Distributed GPU training places sustained demands on data center networks. As more servers participate in AllReduce, AllGather and All-to-All operations, the switching fabric must provide enough aggregate capacity to move traffic between different groups of GPUs without creating persistent bottlenecks. Clos network architectures address this scaling challenge through multiple stages of interconnected switches, while bisection bandwidth provides a useful way to evaluate how much traffic the fabric can carry between two halves of a cluster.
1. Why Clos Networks Matter in GPU Fabrics
Large GPU clusters generate communication patterns that differ from ordinary enterprise network traffic. During distributed training, many GPUs may exchange data simultaneously, and a large portion of this traffic travels between servers rather than between users and applications.
A network built around a small number of high-capacity switches can become difficult to expand as the GPU count grows. Port density, uplink capacity, cable count and switch cost eventually limit the size of a single switching layer.
A Clos network addresses this problem by connecting multiple smaller switches across several stages. Instead of requiring one enormous central switch, the fabric distributes connectivity across leaf, spine and, in larger designs, additional aggregation stages.
This architecture is particularly useful for GPU fabrics because it can provide predictable multi-path connectivity, support large endpoint populations and scale through repeatable network building blocks.
2. What Is a Clos Network?
A Clos network is a multi-stage switching architecture in which input-side switches connect to intermediate switching stages, which then connect to output-side switches. The architecture was originally developed to build large switching systems from smaller switching elements.
In modern data centers, leaf-spine networks are a widely used Clos-style implementation. Servers connect to leaf switches, and each leaf connects to multiple spine switches. The spine layer provides paths between different leaf groups.
A simplified two-tier design contains:
Leaf switches: Connect GPU servers, storage systems or other network endpoints.
Spine switches: Connect leaf switches and provide paths between different parts of the fabric.
Uplinks: Connect each leaf to the spine layer and determine how much aggregate traffic can leave the leaf.
Downlinks: Connect leaf switches to servers and determine the aggregate endpoint-facing capacity.
For larger fabrics, additional stages may be introduced. A three-tier Clos architecture can use leaf, spine and super-spine layers to extend the network beyond the port capacity of a two-tier design.
3. How a Leaf-Spine Clos Fabric Works
In a conventional leaf-spine topology, every leaf switch connects to every spine switch within the relevant fabric domain. Servers attached to different leaf switches can communicate through the spine layer.
For example, when GPU Server A connects to Leaf 1 and GPU Server B connects to Leaf 4, traffic travels from the source server to Leaf 1, crosses an available spine path and reaches Leaf 4 before being delivered to the destination server.
When the endpoints are connected to the same leaf, traffic may remain within that switch and avoid a spine traversal.
This structure provides several useful characteristics:
Predictable hop counts between different leaf groups.
Multiple paths between endpoint groups.
Horizontal expansion by adding leaf switches and corresponding spine capacity.
More distributed switching capacity than a single large central switch.
Compatibility with load-balancing and multipath routing mechanisms.
The number of available paths and the bandwidth of each path depend on the physical connections, switch port configuration and routing implementation. A leaf-spine diagram alone does not establish that the fabric is non-blocking.
4. What Is Bisection Bandwidth?
Bisection bandwidth measures the aggregate network capacity available across a cut that divides a network into two groups of approximately equal size. It is a useful metric for evaluating how much traffic can move between different parts of a GPU cluster.
Imagine dividing a cluster into Group A and Group B, each containing half of the GPU servers. The network links that must carry traffic between the two groups form the bisection cut.
The bisection bandwidth is determined by the capacity of the links crossing that cut, subject to the network topology and the available paths.
Bisection bandwidth:
\(B_{\text{bis}}=\sum_{e\in C} C_e\)
Where \(C\) is the set of links crossing the selected bisection cut, and \(C_e\) is the usable capacity of each link.
This expression describes the aggregate capacity across the cut in one direction when link capacities are counted in that direction. If a source defines bisection bandwidth as a bidirectional total, the two directions may be added together. Comparisons must therefore use the same convention.
In a more general network, the relevant bisection is the minimum-capacity cut among balanced partitions, rather than simply any convenient division of the servers.
5. Why Bisection Bandwidth Is Important for GPU Training
Distributed GPU training often requires simultaneous communication between many servers. A network may provide high bandwidth to individual servers but still perform poorly when traffic must cross between large groups of endpoints.
Bisection bandwidth helps reveal this difference. It measures the fabric's ability to support traffic across the cluster rather than focusing only on individual server-facing port speeds.
It is particularly relevant to:
AllReduce: Gradient synchronization can generate substantial traffic between distributed GPU workers.
AllGather: Data distributed across multiple GPUs must be collected and made available to participating workers.
ReduceScatter: Reduced data is distributed across participants, requiring communication across the fabric.
All-to-All: Many GPUs exchange different data segments with many other GPUs, potentially creating substantial cross-fabric traffic.
Model parallelism: Tensor and pipeline parallel workloads may exchange activations, gradients and intermediate results between servers.
High bisection bandwidth can reduce the likelihood that cross-cluster communication becomes the dominant bottleneck. However, it does not guarantee low latency or high application throughput. Congestion, routing, message size, endpoint performance and collective algorithms also influence results.
6. Full-Bisection and Non-Blocking Network Design
A network with full bisection bandwidth is designed so that the available capacity across a balanced cut can support the intended simultaneous communication demand without oversubscribing that cut.
In a balanced Clos fabric, a common design objective is to provide enough uplink and inter-stage capacity to match the aggregate endpoint bandwidth that must cross the network.
For a simplified symmetric two-tier leaf-spine network, this often means that each leaf has equal aggregate downlink and uplink capacity. Under the assumed traffic model and a suitable switching architecture, this can support a full-bisection design.
Non-blocking is a stronger system-level property than simply having equal port counts. The switching fabric must also provide sufficient internal switching capacity, appropriate path availability and a routing configuration that can carry the required traffic patterns.
7. Understanding Network Oversubscription Ratios
Oversubscription describes the relationship between the aggregate bandwidth of server-facing ports and the aggregate bandwidth of uplinks connecting a switch to the next network stage.
Leaf oversubscription ratio:
\(\text{Oversubscription}=\frac{\text{Aggregate downlink bandwidth}}{\text{Aggregate uplink bandwidth}}\)
A ratio of 1:1 means that downlink and uplink bandwidth are equal. A ratio of 2:1 means that the aggregate downlink capacity is twice the uplink capacity.
| Oversubscription ratio | Downlink capacity | Uplink capacity | Interpretation |
|---|---|---|---|
| 1:1 | 400 Tb/s | 400 Tb/s | Equal endpoint-facing and uplink capacity |
| 2:1 | 400 Tb/s | 200 Tb/s | Uplink capacity is half of downlink capacity |
| 3:1 | 600 Tb/s | 200 Tb/s | Greater potential contention under simultaneous traffic |
| 4:1 | 800 Tb/s | 200 Tb/s | High oversubscription relative to endpoint capacity |
These values are illustrative aggregate bandwidth examples, not recommended configurations for every GPU fabric. An oversubscribed design may be appropriate when measured traffic patterns do not require all endpoints to transmit at full rate simultaneously. For communication-intensive GPU workloads, sustained all-to-all exchanges can expose oversubscription much more quickly than many ordinary enterprise applications.
8. Calculating Bisection Bandwidth in a Two-Tier Clos Fabric
Consider a simplified fabric with eight leaf switches. Each leaf connects to 32 GPU server ports operating at 400 Gb/s and has 16 uplinks operating at the same line rate.
The aggregate server-facing bandwidth per leaf is:
\(32\times400=12.8\text{ Tb/s}\)
The aggregate uplink bandwidth per leaf is:
\(16\times400=6.4\text{ Tb/s}\)
The leaf oversubscription ratio is therefore 2:1.
Across eight leaves, the aggregate endpoint-facing capacity is 102.4 Tb/s. If a balanced cut separates four leaves from the other four, the four leaves on one side have 25.6 Tb/s of aggregate uplink capacity across that cut, assuming their uplinks connect through the relevant spine paths and the fabric has no additional bottleneck.
Under these assumptions, the one-direction bisection capacity for this partition is limited to 25.6 Tb/s. The result is lower than the 51.2 Tb/s of endpoint-facing capacity attached to those four leaves.
This example illustrates why counting server ports alone can overstate the amount of traffic that can cross between two halves of a cluster.
9. Switch Radix and Clos Network Scalability
Switch radix is the number of ports available on a switching device. It directly affects the number of endpoints and other switches that can be connected within a given topology.
In a two-tier Clos design, each leaf requires ports for server connections and spine uplinks. Each spine requires enough ports to connect to the intended leaf population.
For a simplified design in which each leaf connects to every spine, the port requirements can be expressed as:
Leaf port requirement: \(P_L=D_L+S\)
Spine port requirement: \(P_S=L\)
Where \(D_L\) is the number of server-facing ports per leaf, \(S\) is the number of spine switches, and \(L\) is the number of leaf switches.
These relationships assume direct leaf-to-spine connections and one physical port per connection. Breakout cables, multi-lane interfaces and different port speeds can change the physical port accounting.
As the cluster grows, the number of leaf switches may exceed the available port capacity of the spine layer. Additional stages or larger-capacity switches may then be required.
10. Two-Tier and Three-Tier Clos Architectures
The appropriate number of switching stages depends on the size of the GPU fabric, switch radix, port speeds and target oversubscription.
| Architecture | Typical structure | Advantages | Design considerations |
|---|---|---|---|
| Two-tier Clos | Leaf and spine | Relatively simple topology, predictable hop count and straightforward expansion | Spine port capacity can limit the total number of leaves |
| Three-tier Clos | Leaf, spine and super-spine | Supports larger endpoint populations and additional fabric expansion | More stages, switches, cabling and routing complexity |
| Multi-plane Clos | Two or more separate switching planes | Can provide path diversity and improved failure isolation | Requires consistent endpoint mapping and independent path capacity |
Two-tier designs are often suitable for a bounded cluster where the spine layer can accommodate all leaf switches. Three-tier designs extend the fabric when the leaf population or aggregate capacity exceeds the practical limits of the two-tier structure.
Multi-plane designs can be implemented with either two-tier or multi-stage architectures. Plane separation is a separate design dimension from the number of Clos stages.
11. Clos Topology and Rail-Optimized GPU Fabrics
Clos topology and rail optimization address different aspects of GPU network architecture. Clos defines how switches are interconnected across the fabric, while rail optimization organizes corresponding GPU-facing network connections across compute nodes.
In a rail-optimized Clos fabric, corresponding NIC ports from different servers connect to the same rail-specific leaf group. The Clos switching stages then provide scalable connectivity between those groups.
This combination can provide predictable paths for rail-aligned communication while preserving multiple network paths between different server groups.
For example, a cluster with eight NIC positions per server may use eight logical rails. Each rail can have its own leaf-switch group and corresponding spine connectivity, or multiple rails may share a larger switching domain depending on the design.
The choice affects port utilization, switch count, cable count, path diversity and the amount of traffic that can cross between rails.
12. Routing and Load Balancing Across Clos Paths
A Clos fabric can provide multiple physical paths between two endpoints, but the routing system must distribute traffic effectively to make use of that capacity.
Common approaches include equal-cost multipath (ECMP), adaptive routing and flow-aware load balancing. Their behavior depends on the network technology, switch capabilities and traffic characteristics.
ECMP: Distributes flows across equal-cost paths, commonly using a hash of selected packet fields.
Adaptive routing: Selects paths based on network conditions or congestion information where supported.
Flow-aware distribution: Attempts to distribute traffic while considering flow characteristics and path utilization.
Collective-aware communication: Allows communication software to select algorithms and paths based on the cluster topology.
Traditional flow hashing can cause uneven utilization when a small number of large flows happen to map to the same path. Adaptive routing may improve distribution for some workloads, but it introduces implementation-specific behavior and does not eliminate all congestion.
For GPU fabrics, routing behavior should be evaluated under representative collective operations rather than relying only on theoretical path counts.
13. Bisection Bandwidth and AllReduce Communication
AllReduce is a fundamental collective operation in distributed training. It combines data from multiple GPUs and distributes the reduced result to participating workers.
Ring-based AllReduce divides data into chunks and transfers them through a sequence of neighboring participants. Each GPU performs reduction and forwarding operations until all participants have the required result.
In a large cluster, some communication steps cross leaf groups and consume bandwidth in the Clos fabric. The bisection capacity influences how much simultaneous traffic can pass between different groups of workers.
Other collective algorithms, including tree-based methods, may generate different traffic patterns and have different latency and bandwidth characteristics. The most suitable algorithm depends on message size, participant count, topology and communication-library implementation.
A high-bisection Clos fabric provides more aggregate capacity for cross-cluster communication, but application performance still depends on how the collective algorithm maps its traffic onto available paths.
14. Bisection Bandwidth and All-to-All Traffic
All-to-All communication is particularly demanding because each GPU may send different data to many other GPUs. This pattern is common in some distributed model-parallel and Mixture of Experts workloads.
Unlike a communication pattern that mainly exchanges data between neighboring ranks, All-to-All can generate traffic across many leaf groups simultaneously. This makes it useful for evaluating whether the fabric can sustain distributed communication without severe contention.
When the network is oversubscribed, simultaneous transfers from many servers can compete for the same uplinks or spine resources. Congestion can increase queueing delay and reduce effective throughput.
For this reason, All-to-All benchmarks can expose limitations that are less visible in isolated point-to-point tests.
15. InfiniBand and RoCE Implementations of Clos Fabrics
Clos architectures can be implemented using both InfiniBand and Ethernet-based RoCE networks. The physical switching topology may look similar, but the network technologies use different transport and congestion-management mechanisms.
| Design area | InfiniBand Clos fabric | RoCE Clos fabric |
|---|---|---|
| Network infrastructure | InfiniBand switches and compatible adapters | Ethernet switches and compatible RDMA NICs |
| Transport | InfiniBand transport architecture | RDMA over Converged Ethernet |
| Routing | Subnet and fabric routing mechanisms, with adaptive routing where supported | Ethernet routing and ECMP or other supported multipath mechanisms |
| Congestion management | InfiniBand-specific congestion control and fabric mechanisms | Often uses ECN-based signaling and transport response; PFC may be configured where required |
| Operational focus | Fabric management, subnet configuration and adapter compatibility | QoS, queue management, ECN, loss behavior and end-to-end configuration |
Both technologies can support large GPU fabrics. The choice depends on existing infrastructure, supported hardware, operational requirements and the target workload.
In RoCE deployments, congestion management must be designed across the complete path. PFC is not a substitute for adequate capacity planning or effective congestion control, and poorly designed pause behavior can introduce head-of-line blocking and deadlock risks.
16. Optical Connectivity and High-Radix Switching
As a GPU fabric expands, connections between leaf and spine switches increasingly require high-speed interconnects. Optical transceivers and fiber links are often used where reach, cable management or aggregate bandwidth requirements make direct electrical connections unsuitable.
High-radix switches can reduce the number of switching stages or increase the number of endpoints connected within a particular layer. However, realizing the intended capacity requires sufficient high-speed optical or electrical links between the switches.
Common interconnect choices include:
DAC: Suitable for supported short-reach connections within racks or between nearby devices.
AEC: Provides active electrical signal conditioning for selected high-speed copper interconnect applications.
AOC: Integrates optical transmission into a cable assembly for supported switch and server connections.
Pluggable optical transceivers: Provide modular optical connectivity for leaf-spine and higher-stage switch links.
For high-speed optical links, engineers should verify module compatibility, wavelength, fiber type, connector configuration, optical power budget and supported link distance. Aggregate capacity calculations should use the actual configured line rate and account for any port breakout arrangement.
Uneven optical link performance can also create practical bandwidth limitations. Monitoring FEC statistics, lane-level errors and optical diagnostics helps identify links that are operating with reduced margin.
17. Common Mistakes in Clos Network Capacity Planning
Using total server bandwidth as the bisection bandwidth
Aggregate server-facing capacity does not equal the capacity available across a balanced network cut. Uplink and inter-stage bandwidth must also be considered.
Assuming that every leaf-to-spine connection creates a non-blocking fabric
Full connectivity between layers does not guarantee sufficient aggregate capacity. Port counts, link rates, switch internal capacity and oversubscription all matter.
Ignoring the traffic pattern
AllReduce, AllGather and All-to-All can produce different communication patterns. A design optimized for one workload may not deliver the same performance for another.
Counting only physical ports
Port speed, breakout configuration, lane mapping and actual usable bandwidth must be included. A port count without line-rate information is not enough.
Ignoring routing behavior
Multiple physical paths do not guarantee balanced traffic distribution. Hash collisions, flow concentration and congestion can reduce effective network capacity.
Assuming full bisection guarantees application performance
GPU communication also depends on NIC throughput, PCIe topology, GPU-to-NIC affinity, software configuration, congestion and collective algorithm efficiency.
18. A Practical Clos Fabric Design and Validation Process
A reliable GPU fabric design should begin with the workload and endpoint requirements, then translate them into switching capacity, topology and physical connectivity.
Determine the endpoint population: Identify the number of GPU servers, GPUs per server, NIC ports per server and required network planes.
Calculate endpoint bandwidth: Multiply the number of active ports by their configured line rate, keeping per-direction and aggregate figures clearly separated.
Select the Clos stages: Determine whether a two-tier leaf-spine network is sufficient or whether additional switching stages are required.
Define the oversubscription target: Calculate downlink-to-uplink ratios at each relevant stage and evaluate expected traffic concentration.
Evaluate bisection capacity: Examine balanced cuts through the fabric and verify that inter-stage links provide the required aggregate capacity.
Plan routing and congestion management: Confirm multipath behavior, traffic distribution, queue configuration and failure handling.
Design physical connectivity: Select suitable DAC, AEC, AOC or optical transceiver connections based on reach, speed and compatibility.
Validate with workload benchmarks: Measure point-to-point bandwidth, collective performance, All-to-All throughput and sustained cluster behavior.
Test failure scenarios: Measure the effect of switch, link or transceiver failures on available bandwidth and training stability.
Validation should include both normal operation and degraded conditions. A fabric that meets its bandwidth target only when every link is available may require additional planning for maintenance and failure recovery.
19. Conclusion
Clos network design provides a scalable switching architecture for large GPU fabrics, while bisection bandwidth helps quantify the aggregate capacity available between different parts of the cluster. Together, these concepts provide a practical foundation for evaluating network scalability, oversubscription and communication performance.
A well-designed GPU fabric must balance leaf and spine capacity, switch radix, network stages, routing behavior and physical link performance. Full-bisection designs can support demanding distributed communication patterns, but their effectiveness still depends on endpoint capabilities, traffic distribution and application-level communication behavior.