SFP28 and QSFP28 serve distinct roles in a network. SFP28 carries a single 25Gbps lane and is used for server access, Top-of-Rack connections, and 5G fronthaul. QSFP28 aggregates four 25Gbps lanes into 100Gbps and is used for uplinks, aggregation, leaf-spine fabric, and 4x25G breakout. The two form factors are physically incompatible, and the selection should be driven by the port type, lane architecture, breakout requirements, power budget, and the network layer being designed.
1. What Is SFP28?
SFP28 is a single-lane 25Gbps optical module form factor built on the SFP+ physical footprint. It carries one 25Gbps electrical lane using NRZ modulation and is widely deployed for 25G server access, Top-of-Rack switching, enterprise aggregation, storage networking, and 5G fronthaul[reference:0].
SFP28 modules typically consume around 1.5W to 2W depending on reach and optics type, with short-reach and AOC variants often below 1W and longer-reach single-mode variants approaching 2W[reference:1][reference:2]. The form factor is backward compatible with SFP+ cages at 10G, but an SFP+-only port generally cannot operate an SFP28 module at 25G.
In 5G networks, SFP28 is the workhorse for eCPRI and O-RAN fronthaul over 25GbE, providing the symmetric uplink and downlink capacity required for centralized and cloud RAN architectures[reference:3].
2. What Is QSFP28?
QSFP28 stands for Quad Small Form-factor Pluggable 28. It combines four 25Gbps lanes in a single module to deliver 100Gbps aggregate bandwidth. QSFP28 is the mainstream 100G interface for switch uplinks, aggregation layers, leaf-spine fabric, and high-density 100G links in cloud and enterprise data centers[reference:4][reference:5].
QSFP28 modules typically consume around 3W to 5W depending on reach and optics type, with short-reach variants near 3.5W and longer-reach ER-class optics approaching 5W[reference:6][reference:7]. While the per-module power is higher than SFP28, a single 100G QSFP28 link can replace four 25G SFP28 links at the uplink level, which often improves power efficiency per 100G of bandwidth.
A defining capability of QSFP28 is breakout support. A single 100G QSFP28 port can be split into four independent 25G interfaces using a breakout cable and compatible SFP28 modules on the downstream end. This 100G-to-4x25G breakout is common in leaf-spine architectures, where spine switches use QSFP28 ports to connect to multiple leaf switches with 25G server access[reference:8][reference:9].
3. Key Specifications
| Item | SFP28 | QSFP28 |
|---|---|---|
| Lane architecture | 1 × 25Gbps lane | 4 × 25Gbps lanes |
| Aggregate speed | 25Gbps | 100Gbps |
| Modulation | NRZ | NRZ per lane (typical for 100G Ethernet) |
| Physical size | Approx. 13.4mm × 56.5mm | Approx. 18.4mm × 73.4mm |
| Cage compatibility | Physically incompatible with QSFP28 cages | Physically incompatible with SFP28 cages |
| Typical power | Roughly 1.5–2W | Roughly 3–5W per module |
| Breakout support | Not applicable as a single-lane form factor | Supports 4 × 25G breakout when the switch and cabling support it |
| Common optical connectors | LC duplex for most optics | MPO/MTP for SR4/PSM4; LC duplex for CWDM4, LR4, ER4 |
| Representative reach | SR up to 70m OM3 / 100m OM4; LR up to 10km | SR4 up to 70m OM3 / 100m OM4; CWDM4 up to 2km; LR4 up to 10km; ER4 up to 40km |
| Primary network role | Server access, ToR, edge links, 5G fronthaul | Uplinks, aggregation, leaf-spine fabric, high-density 100G |
4. Physical Incompatibility and Breakout Adapters
5. Power, Density, and Cost Perspective
SFP28
Lower per-port power, which simplifies thermal design in high-density 25G access platforms.
Mature 25G NRZ ecosystem with broad SR, LR, ER, DWDM, DAC, and AOC availability.
Cost-effective for server access and fronthaul ports where 25G per port matches the traffic profile.
QSFP28
Higher per-module power, but one 100G module can replace four 25G links at the uplink level, improving efficiency per 100G of bandwidth.
Higher front-panel 100G density than four discrete SFP28 ports for the same aggregate throughput.
Breakout capability allows a 100G spine port to serve four 25G leaf connections, simplifying cabling and port utilization.
A published comparison notes that a direct QSFP28 100G link can be more cost-effective and significantly more power-efficient than four separate SFP28 25G links for the same 100G aggregate, with reported figures around 5.5W for QSFP28 versus roughly 14W for 4×SFP28[reference:12]. Actual values depend on the specific modules, reach, and platform design.
6. Application Fit
6.1 SFP28 for 25G Access and Fronthaul
SFP28 is the default 25G interface for server access, Top-of-Rack switching, storage networking, virtualized clusters, and 5G fronthaul. In a data center, servers connect to leaf switches through SFP28 ports at 25G. In 5G, SFP28 carries eCPRI and O-RAN fronthaul traffic over 25GbE, supporting the bandwidth and latency requirements of centralized and cloud RAN[reference:13].
6.2 QSFP28 for 100G Aggregation and Leaf-Spine
QSFP28 is used for switch uplinks, aggregation layers, and spine-leaf fabric. In a typical leaf-spine design, leaf switches provide 25G SFP28 server access and use QSFP28 uplinks at 100G to connect to spine switches. Spine switches use QSFP28 ports for 100G interconnect and can break out those ports into 4 × 25G to connect multiple leaf switches efficiently[reference:14][reference:15].
6.3 Breakout and Mixed Design
QSFP28 breakout allows one 100G port to serve four 25G downstream connections through a breakout cable and SFP28 modules at the far end. This is common in leaf-spine fabrics and in racks where a 100G uplink is distributed to multiple 25G server ports. The switch must support breakout mode, and the cabling and optics must be matched to the breakout configuration.
7. Selection Guidance
Start with the port type on the switch or NIC and the required per-port speed. For 25G server access, storage, or fronthaul, SFP28 provides a low-power, cost-effective solution with a mature optics portfolio. For 100G uplinks, aggregation, or spine interconnect, QSFP28 provides the required bandwidth and can support 4 × 25G breakout to connect downstream 25G devices.
Verify whether the switch port supports breakout, the correct breakout cable or adapter is available, and the far-end optics are compatible. Do not attempt to insert an SFP28 module into a QSFP28 cage or vice versa. Use the switch datasheet, optics compatibility list, and breakout configuration guide as the basis for selection.
8. Frequently Asked Questions
No. SFP28 and QSFP28 use different cage sizes and pin definitions. Direct insertion is not possible. To connect an SFP28 link to a QSFP28 port, use a dedicated QSFP28-to-SFP28 adapter or a breakout cable designed for that purpose.
Yes, when the switch and port support breakout mode. A 100G QSFP28 port can be split into four 25G interfaces using a breakout cable and SFP28 optics on the downstream end. Not all QSFP28 ports support breakout, so check the switch specification.
Per module, yes, QSFP28 typically consumes more power (around 3–5W versus 1.5–2W for SFP28). However, for a 100G uplink, one QSFP28 module can replace four SFP28 modules, so the power per 100G of bandwidth can be lower with QSFP28 depending on the comparison.
SFP28 is the common 25G interface for 5G eCPRI and O-RAN fronthaul. QSFP28 is used at aggregation and transport layers where 100G uplinks are required, but the fronthaul radio link itself typically uses SFP28 at 25G.
Breakout allows a single 100G switch port to serve four 25G downstream connections. This improves port utilization and can simplify cabling in leaf-spine fabrics where a spine port needs to connect to multiple 25G leaf or server ports.
9. Conclusion
SFP28 and QSFP28 are complementary interfaces at different levels of the network. SFP28 provides single-lane 25G connectivity for server access, ToR, storage, and 5G fronthaul. QSFP28 aggregates four 25G lanes into 100G for uplinks, aggregation, spine-leaf fabric, and breakout applications. They are not physically interchangeable, but they can be connected through breakout cables and adapters. The correct choice depends on the port type, required bandwidth, breakout needs, power budget, and network layer.
Designing 25G access and 100G aggregation layers?
Evaluate SFP28 and QSFP28 modules based on port compatibility, breakout support, power budget, and reach requirements.
Explore C-LIGHT optical modules for 25G and 100G network connectivity
TEL:+86 132 6656 7067




















































>
>
>
>
>
>
>
>