Products
Solutions
Articles
About Us
WDM
Others
Network solutions for customers in different industries
More solutionSwitches compatibility
WDM
100G
Your trusted network solutions partner
Check the blogC-light QSFP+: Quad small form factor pluggable transceivers, capable of data rates up to 40Gb/s and 56Gb/s. C-LIGHT offers distance 100m SR4, 2km SLR4, 10km LR4, 20km LR4, 40km ER4 options. 850nm MPO, 830/890nm bi-direction, 1310nm, and 1550nm options. Range of passive DAC cables and AOC cables available.
QSFP 40g 40km testing log:
Ethernet1/49
transceiver is present
type is QSFP-40G-ER4
name is OEM
part number is QSFP+-40G-ER4
revision is 1A
serial number is CL191211001
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 9/125um fiber is 40 km
cisco id is 13
cisco extended id number is 192
Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 20.37 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.24 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 34.57 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 1.37 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -15.68 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:2 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 20.37 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.24 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 33.76 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 1.96 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -14.31 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:3 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 20.37 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.24 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 34.57 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 1.76 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -13.56 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:4 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 20.37 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.24 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 33.23 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.56 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -14.20 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Ethernet1/51
transceiver is present
type is QSFP-40G-ER4
name is OEM
part number is QSFP+-40G-ER4
revision is 1A
serial number is CL191211002
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 9/125um fiber is 40 km
cisco id is 13
cisco extended id number is 192
Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 26.74 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 35.04 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.60 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -14.81 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:2 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 26.74 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 35.04 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.62 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -13.56 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:3 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 26.74 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 36.11 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.37 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -12.83 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:4 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 26.74 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 34.50 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.19 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -12.29 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
type is QSFP-40G-ER4
name is OEM
part number is QSFP+-40G-ER4
revision is 1A
serial number is CL191211003
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 9/125um fiber is 40 km
cisco id is 13
cisco extended id number is 192
Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 25.48 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 34.23 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.10 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -16.02 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:2 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 25.48 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 35.04 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.25 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -14.68 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:3 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 25.48 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 35.57 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.48 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -13.18 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:4 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 25.48 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.25 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 35.50 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.11 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -13.37 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
type is QSFP-40G-ER4
name is OEM
part number is QSFP+-40G-ER4
revision is 1A
serial number is CL191211004
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 9/125um fiber is 40 km
cisco id is 13
cisco extended id number is 192
Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 22.49 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.23 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 32.15 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.63 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -16.77 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:2 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 22.49 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.23 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 31.89 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 0.96 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -15.68 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:3 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 22.49 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.23 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 33.50 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 1.18 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -14.43 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Lane Number:4 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 22.49 C 80.00 C -10.00 C 75.00 C -5.00 C
Voltage 3.23 V 3.70 V 2.90 V 3.59 V 3.00 V
Current 31.89 mA 75.00 mA 10.00 mA 70.00 mA 15.23 mA
Tx Power 1.03 dBm 5.49 dBm -7.01 dBm 4.99 dBm -6.00 dBm
Rx Power -13.97 dBm 1.99 dBm -23.01 dBm 0.99 dBm -20.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
Ethernet1/50
transceiver is not present
Ethernet1/51
transceiver is not present
Ethernet1/52
transceiver is not present
Ethernet1/53
transceiver is not present
Ethernet1/54
transceiver is not present
Product video: